Presently, the “negative sequence current method” is widely used in field-testing to determine torsional vibration characteristics of steam turbine generator rotor systems. The natural frequencies of lower modes of vibration can be determined effectively in this way, but higher modes cannot be readily excited. To understand this phenomenon, modal analysis was employed to digitally simulate the dynamic response obtained in torsional vibration testing of a 200MW steam turbine generator rotor system. The calculations were consistent with field experimental results, showing that higher modes are difficult to excite by this method. The research also indicated that higher modes could be excited by certain experimental procedures. The conclusions provide guidelines for future field-testing of large-scale systems.

1.
Balance
,
J. W.
, and
Goldberg
,
S.
,
1973
, “
Subsynchronous Resonance in Series Compensated Transmission Lines
,”
IEEE Trans. Power Appar. Syst.
,
92
(
5
), pp.
1649
1658
.
2.
Hall
,
M. C.
, and
Hodges
,
D. A.
,
1976
, “
Experience with 500 KV Subsynchronous Resonance and Resulting Turbine Generator Shaft Damage at Mohave Generation Station
,”
IEEE Trans. Power Deliv.
,
12
(
1
), pp.
406
417
.
3.
Eli
,
Katz
, and
Tang
,
J.
,
1989
, “
Comparison of SSR Calculations and Test Results
,”
IEEE Transactions on Power Systems
,
4
(
1
), pp.
336
344
.
4.
Subsynchronous Resonance Working Group of the System Dynamic Performance Subcommittee
,
1992
, “
Reader’s Guide to Subsynchronous Resonance
,”
IEEE Transactions on Power Systems
,
7
(
1
), pp.
150
157
.
5.
Edris
,
A. A.
,
1993
, “
Subsynchronous Resonance Countermeasure Using Phase Imbalance
,”
IEEE Transactions on Power Systems
,
8
(
4
), pp.
1438
1447
.
6.
Hannett
,
L. N.
, and
Mello
,
F. P.
,
1990
, “
Mechanical Countermeasures to Subsynchronous Torsional Instability
,”
IEEE Transactions on Power Systems
,
5
(
4
), pp.
1146
1150
.
7.
Hauer
,
J. F.
,
Mittelstadt
,
W. A.
,
Piwko
,
R. J.
,
Damsky
,
B. L.
, and
Eden
,
J. D.
,
1996
, “
Modulation and SSR Tests Performed on the BPA 500 KV Thyristor Controlled Series Capacitor Unit at Slatt Substation
,”
IEEE Transactions on Power Systems
,
11
(
2
), pp.
801
806
.
8.
Pilotto
,
L. A. S.
,
Bianco
,
A.
,
Long
,
W. F.
, and
Edris
,
A. A.
,
2003
, “
Impact of TCSC Control Methodologies on Subsynchronous Oscillations
,”
IEEE Trans. Power Deliv.
,
18
(
1
), pp.
243
252
.
9.
Joyce
,
J. S.
,
Kulig
,
T.
, and
Lambrecht
,
D.
,
1978
, “
Torsional Fatigue of Turbine-Generator Shafts Caused by Different Electrical System Faults and Switching Operations
,”
IEEE Trans. Power Appar. Syst.
,
97
(
5
), pp.
1965
1977
.
10.
Jackson
,
M. C.
, and
Umans
,
S. D.
,
1980
, “
Turbine-Generator Shaft Torques and Fatigue: Part III-Refinements to Fatigue Model and Test Results
,”
IEEE Trans. Power Appar. Syst.
,
99
(
3
), pp.
1259
1268
.
11.
Gonzalez
,
A. J.
,
Kung
,
G. C.
,
Raczkowski
,
C.
,
Taylor
,
C. W.
, and
Thonn
,
D.
,
1984
, “
Effects of Single- and three-pole Switching and High-Speed Reclosing on Turbogenerator Shafts and blades
,”
IEEE Trans. Power Appar. Syst.
,
103
(
11
), pp.
3218
3228
.
12.
Walker
,
D. N.
,
Bowler
,
C. E. J.
,
Jackson
,
R. L.
, and
Hodges
,
D. A.
,
1975
, “
Results of Subsynchronous Resonance Test at Mohave
,”
IEEE Trans. Power Appar. Syst.
,
94
(
5
), pp.
1878
1889
.
13.
Hammons
,
T. J.
, and
Goh
,
M. W.
,
2000
, “
Turbine, Generator, System Modeling and Impact of Variable-Frequency Ripple Currents on Torsional Stressing of Generators in Poland and Sweden: Lithuania/Poland and Sweden/Poland HVDC Links
,”
IEEE Transactions on Energy Conservation
,
15
(
4
), pp.
384
394
.
14.
Faried
,
S. O.
,
Billinton
,
R.
,
Aboreshaid
,
S.
, and
Mahmud
,
F. F.
,
2000
, “
Effect of Adaptive Short Time Compensation on the Stochastic Behavior of Turbine-Generator Shaft Torsional Torques
,”
IEEE Transactions on Energy Conservation
,
15
(
3
), pp.
305
311
.
15.
Twerdochlib
,
M.
,
Miller
,
R. C.
,
Osborne
,
R. L.
,
Lemak
,
T. A.
,
Repplier
,
C. C.
,
Morrison
,
D. R.
, and
Boomgaard
,
D. J.
,
1988
, “
Two Recent Developments in Monitors for Large Turbine Generators
,”
IEEE Transactions on Energy Conversion
,
3
(
3
), pp.
653
659
.
16.
Moran
,
C. G.
, and
Brown
,
M. D.
,
1997
, “
Coherency-Based Low Order Models for Shaft Systems of Turbine-Generator Sets
,”
IEEE Transactions on Energy Conversion
,
12
(
3
), pp.
217
224
.
17.
Nyati
,
S.
,
Wegner
,
C. A.
,
Delmerico
,
R. W.
,
Piwko
,
R. J.
,
Baker
,
D. H.
, and
Edris
,
A.
,
1994
, “
Effectiveness of Thyristor Controlled Series Capacitor in Enhancing Power System Dynamics: An Analog Simulator Study
,”
IEEE Trans. Power Deliv.
,
9
(
2
), pp.
1018
1027
.
18.
Lin
,
X. N.
,
Zhang
,
P. L.
, and
Malik
,
O. P.
,
2002
, “
Wavelet Based Scheme for Detection of Torsional Oscillation
,”
IEEE Trans. Power Appar. Syst.
,
17
(
4
), pp.
1096
1101
.
19.
Hsu
,
Y. Y.
, and
Jeng
,
L. H.
,
1992
, “
Analysis of Torsional Oscillations Using an Artificial Neural Network
,”
IEEE Transactions on Energy Conversion
,
7
(
4
), pp.
684
690
.
20.
Lu
,
S. Y.
,
1989
, “
The Torsional Vibration Test and Analysis of the #6 Steam Turbine Generator Rotor System at Qinling Power Plant
,”
Journal of Power Technology
,
20
(
2
), pp.
133
141
.
You do not currently have access to this content.