Stagnation region heat transfer measurements have been acquired on two large cylindrical leading edge test surfaces having a four to one range in leading edge diameter. Heat transfer measurements have been acquired for six turbulence conditions including three grid conditions, two aero-combustor conditions, and a low turbulence condition. The data have been run over an eight to one range in Reynolds numbers for each test surface with Reynolds numbers ranging from 62,500 to 500,000 for the large leading edge and 15,625 to 125,000 for the smaller leading edge. The data show augmentation levels of up to 110% in the stagnation region for the large leading edge. However, the heat transfer results for the large cylindrical leading edge do not appear to infer a significant level of turbulence intensification in the stagnation region. The smaller cylindrical leading edge shows more consistency with earlier stagnation region heat transfer results correlated on the TRL parameter. These results indicate that the intensification of approaching turbulence is more prevalent with the more rapid straining of the smaller leading edge. The downstream regions of both test surfaces continue to accelerate the flow but at a much lower rate than the leading edge. Bypass transition occurs in these regions providing a useful set of data to ground the prediction of transition onset and length over a wide range of Reynolds numbers and turbulence intensity and scales.
Skip Nav Destination
Article navigation
January 2013
Research-Article
The Influence of Leading Edge Diameter on Stagnation Region Heat Transfer Augmentation Including Effects of Turbulence Level, Scale, and Reynolds Number
Preethi Gandavarapu,
Preethi Gandavarapu
e-mail: preethi.gandavarapu@my.und.edu
Search for other works by this author on:
Forrest E. Ames
Forrest E. Ames
e-mail: forrest.ames@engr.und.edu
Mechanical Engineering Department,
University of North Dakota
,243 Centennial Drive, Stop 8359
,Grand Forks, ND 58202-8359
Search for other works by this author on:
Preethi Gandavarapu
e-mail: preethi.gandavarapu@my.und.edu
Forrest E. Ames
e-mail: forrest.ames@engr.und.edu
Mechanical Engineering Department,
University of North Dakota
,243 Centennial Drive, Stop 8359
,Grand Forks, ND 58202-8359
Contributed by the International Gas Turbine Institute (IGTI) of ASME for publication in the JOURNALOF TURBOMACHINERY. Manuscript received July 11, 2011; final manuscript received August 10, 2011; published online October 18, 2012. Editor: David Wisler.
J. Turbomach. Jan 2013, 135(1): 011008 (8 pages)
Published Online: October 18, 2012
Article history
Received:
July 11, 2011
Revision Received:
August 10, 2011
Citation
Gandavarapu, P., and Ames, F. E. (October 18, 2012). "The Influence of Leading Edge Diameter on Stagnation Region Heat Transfer Augmentation Including Effects of Turbulence Level, Scale, and Reynolds Number." ASME. J. Turbomach. January 2013; 135(1): 011008. https://doi.org/10.1115/1.4006396
Download citation file:
Get Email Alerts
Related Articles
Effects of Large Scale High Freestream Turbulence and Exit Reynolds Number on Turbine Vane Heat Transfer in a Transonic Cascade
J. Turbomach (April,2009)
On the Calculation of Length Scales for Turbulent Heat Transfer Correlation
J. Heat Transfer (October,2001)
Geometry Effects on Turbulent Flow and Heat Transfer in Internally Finned Tubes
J. Heat Transfer (December,2001)
Related Proceedings Papers
Related Chapters
Cavitating Structures at Inception in Turbulent Shear Flow
Proceedings of the 10th International Symposium on Cavitation (CAV2018)
The Design and Implement of Remote Inclinometer for Power Towers Based on MXA2500G/GSM
International Conference on Mechanical and Electrical Technology, 3rd, (ICMET-China 2011), Volumes 1–3
Natural Gas Transmission
Pipeline Design & Construction: A Practical Approach, Third Edition