A steam ejector refrigeration system with a movable primary nozzle was developed in order to determine the nozzle exit position (NXP) effect on the coefficient of performance (COP). Experimental results show that there exists an optimum NXP for the ejector system investigated herein. The effects of the operating temperature, diffuser size, nozzle throat diameter, and mixing chamber configuration on the COP and critical back pressure were investigated experimentally. It is found that the critical back pressure and COP can be increased by increasing the low temperature evaporator (LTE) temperature and pressure. Although an increase of the high temperature evaporator (HTE) temperature can increase the critical condenser pressure, the system COP does not increase as the HTE temperature increases. The diffuser size significantly affects the critical back pressure but had almost no effect on the system COP. A finned mixing chamber was tested at NXP = 0 mm and NXP = 36 mm. Compared with the regular mixing chamber, the finned mixing chamber can increase the critical back pressure.

References

1.
Chunnanond
,
K.
, and
Aphornratana
,
S.
, 2004, “
Ejectors: Applications in Refrigeration Technology
,”
Renewable Sustainable Energy Rev.
,
8
(
2
), pp.
129
155
.
2.
Huang
,
B. J.
,
Jiang
,
C. B.
, and
Hu
,
F. L.
, 1985, “
Ejector Performance Characteristics and Design Analysis of a Jet Refrigeration System
,”
ASME J. Eng. Gas Turbines Power
,
107
(
3
), pp.
792
802
.
3.
Eames
,
I. W.
,
Aphornratana
,
S.
, and
Haider
,
H.
, 1995, “
A Theoretical and Experimental Study of a Small-Scale Steam Jet Refrigerator
,”
Int. J. Refrig.
,
8
(
2
), pp.
378
386
.
4.
Chen
,
Y. M.
, and
Sun
,
C. Y.
, 1997, “
Experimental Study of the Performance Characteristics of a Steam-Ejector Refrigeration System
,”
Exp. Therm. Fluid Sci.
,
15
(
4
), pp.
384
394
.
5.
Eames
,
I. W.
,
Wu
,
S.
,
Worall
,
M.
, and
Aphornratana
,
S.
, 1999, “
An Experimental Investigation of Steam Ejectors for Applications in Jet-Pump Refrigerators Powered by Low-Grade Heat
,”
Proc. Inst. Mech. Eng.
,
213
(
5
), pp.
351
361
.
6.
Sun
,
D. W.
, 1997, “
Experimental Investigation of the Performance Characteristics of a Steam Jet Refrigeration System
,”
Energy Sources
,
19
(
4
), pp.
349
367
.
7.
Meyer
,
A. J.
,
Harms
,
T. M.
, and
Dobson
,
R. T.
, 2009, “
Steam Jet Ejector Cooling Powered by Waste or Solar Heat
,”
Renewable Energy
,
34
(
1
), pp.
297
306
.
8.
Aphornratana
,
S.
, and
Eames
,
I. W.
, 1997, “
A Small Capacity Steam-Ejector Refrigerator: Experimental Investigation of a System Using Ejector With Movable Primary Nozzle
,”
Int. J. Refrig.
,
20
(
5
), pp.
352
358
.
You do not currently have access to this content.