The thermal management of power electronics presents a significant challenge to thermal engineers due to high power loads coupled with small footprints. Inadequate thermal dissipation of these loads can lead to excessively high equipment temperatures and subsequent system failure. In this study, a unique power electronics-based transformer, called the intelligent universal transformer (IUT), is thermally analyzed using the computational fluid dynamics software ICEPAK. The objective of this work is to examine the use of a finned heat pipe array for the power electronics in the IUT. A design sensitivity study was performed to determine the effect of the number of fins attached to the heat pipe array, the number of heat pipes in the heat pipe array, and the fin material on the steady-state operating temperature of the power electronics. It was determined that a set of 33 copper fins attached to an array of 36 heat pipes on each side of the containment unit is sufficient for continuous operation of the power electronics. This analysis and thermal management solution will be applicable not only to this situation but also to other high density power electronics applications.
Skip Nav Destination
e-mail: amy.fleischer@villanova.edu
Article navigation
March 2011
Research Papers
Thermal Management of a Intelligent Universal Transformer
Ronald Warzoha,
Ronald Warzoha
Department of Mechanical Engineering,
Villanova University
, 800 Lancaster Avenue, Villanova, PA 19085
Search for other works by this author on:
Amy S. Fleischer
Amy S. Fleischer
Department of Mechanical Engineering,
e-mail: amy.fleischer@villanova.edu
Villanova University
, 800 Lancaster Avenue, Villanova, PA 19085
Search for other works by this author on:
Ronald Warzoha
Department of Mechanical Engineering,
Villanova University
, 800 Lancaster Avenue, Villanova, PA 19085
Amy S. Fleischer
Department of Mechanical Engineering,
Villanova University
, 800 Lancaster Avenue, Villanova, PA 19085e-mail: amy.fleischer@villanova.edu
J. Thermal Sci. Eng. Appl. Mar 2011, 3(1): 011002 (7 pages)
Published Online: March 10, 2011
Article history
Received:
April 8, 2010
Revised:
January 24, 2011
Online:
March 10, 2011
Published:
March 10, 2011
Citation
Warzoha, R., and Fleischer, A. S. (March 10, 2011). "Thermal Management of a Intelligent Universal Transformer." ASME. J. Thermal Sci. Eng. Appl. March 2011; 3(1): 011002. https://doi.org/10.1115/1.4003608
Download citation file:
55
Views
Get Email Alerts
Cited By
Simulation and Experimental Study of Two-Phase Gas–Liquid Behavior in Two-Dimensional Porous Medium Based on Lattice Boltzmann Method
J. Thermal Sci. Eng. Appl (February 2025)
Effect of Variation of the Aspect Ratio of Rectangular Twisted Tapes Inserted in a Circular Pipe on the Thermal Performance
J. Thermal Sci. Eng. Appl (February 2025)
Design Optimization of a Shell-and-Tube Heat Exchanger Based on Variable Baffle Cuts and Sizing
J. Thermal Sci. Eng. Appl (February 2025)
Energy-Efficient Three-Wheel Bleedless Electrical Environmental Control System for a Passenger Aircraft
J. Thermal Sci. Eng. Appl (February 2025)
Related Articles
Novel Design of a Miniature Loop Heat Pipe Evaporator for Electronic Cooling
J. Heat Transfer (October,2007)
Operating Characteristic Investigations in Pulsating Heat Pipe
J. Heat Transfer (December,2006)
An Investigation of Flat-Plate Oscillating Heat Pipes
J. Electron. Packag (December,2010)
Characterization and Modeling of the Heat Transfer Performance of Nanostructured Cu Micropost Wicks
J. Heat Transfer (October,2011)
Related Proceedings Papers
Related Chapters
Analysis on Temperature Field of Buried Gas Pipeline by Heat Pipe Technology
Inaugural US-EU-China Thermophysics Conference-Renewable Energy 2009 (UECTC 2009 Proceedings)
Heat Pipes and Others
Thermal Management of Microelectronic Equipment, Second Edition
Numerical Simulation and Experiment for Structure Optimization of Small Gravity Heat Pipe Radiators
International Conference on Mechanical Engineering and Technology (ICMET-London 2011)