Abstract

A thermodynamic study was performed on a vapor compression refrigeration system (VCRS) with domestic liquefied petroleum gas (LPG) as a refrigerant. LPG's coefficient of performance, power consumption, and refrigeration capacity are compared with R134a. There were three condensing temperature settings: 35, 40, and 45 °C, and the evaporation temperatures ranged from −18 °C to +14 °C. It has been observed that the VCRS with domestic LPG consumes less power than that of R134a and it's evident that domestic LPG is compatible with mineral oil. The findings indicate that R134a's performance is fairly comparable. It has been found that the mass flowrate, compressor discharge temperature, and compressor discharge pressure are lower than that of R134a. The experimental investigation reveals that domestic LPG can be a suitable refrigerant in vapor compression refrigeration systems for both refrigeration and cooling applications.

References

1.
United Nations
,
2016
, “
Amendment to the Montreal Protocol on Substances That Deplete the Ozone Layer
,” New York.
2.
Maclaine-Cross
,
I. L.
, and
Leonardi
,
E.
,
1995
, “
Performance and Safety of LPG Refrigerants
,”
Proceedings of the ‘Fuel for Change’ Conference of Australian Liquefied Petroleum Gas Association Ltd.
,
Paradise, QLD, Australia
,
Feb. 28–Mar. 2
, pp.
149
168
.
3.
James
,
R. W.
, and
Missenden
,
J. F.
,
1992
, “
The Use of Propane in Domestic Refrigerators
,”
Int. J. Refrig.
,
15
(
2
), pp.
95
100
.
4.
Lee
,
H.-S.
,
Yoon
,
J.-I.
,
Kim
,
J.-D.
, and
Bansal
,
P.
,
2006
, “
Characteristics of Condensing and Evaporating Heat Transfer Using Hydrocarbon Refrigerants
,”
Appl. Therm. Eng.
,
26
(
10
), pp.
1054
1062
.
5.
Wongwises
,
S.
, and
Chimres
,
N.
,
2005
, “
Experimental Study of Hydrocarbon Mixtures to Replace HFC-134a in a Domestic Refrigerator
,”
Energy Convers. Manage.
,
46
(
1
), pp.
85
100
.
6.
Mani
,
K.
, and
Selladurai
,
V.
,
2008
, “
Experimental Analysis of a New Refrigerant Mixture as Drop-in Replacement for CFC12 and HFC134a
,”
Int. J. Therm. Sci.
,
47
(
11
), pp.
1490
1495
.
7.
Bolaji
,
B. O.
,
2010
, “
Experimental Study of R152a and R32 to Replace R134a in a Domestic Refrigerator
,”
Energy
,
35
(
9
), pp.
3793
3798
.
8.
Fatouh
,
M.
, and
El Kafafy
,
M.
,
2006
, “
Experimental Evaluation of a Domestic Refrigerator Working With LPG
,”
Appl. Therm. Eng.
,
26
(
14–15
), pp.
1593
1603
.
9.
Kadhim
,
S. A.
,
Al-Ghezi
,
M. K. S.
, and
Ashour
,
A. M.
,
2025
, “
Theoretical Analysis of Energy, Exergy, and Environmental Related Aspects of Hydrofluoroolefin Refrigerants as Drop-In Alternatives for R134a in a Household Refrigerator
,”
ASME J. Therm. Sci. Eng. Appl.
,
17
(
2
), p.
021003
.
10.
Caglayan
,
A.
,
Husain
,
S. M.
,
Ipek
,
M.
,
Aynur
,
T. N.
, and
Cadirci
,
S.
,
2022
, “
Dynamic Modeling and Experimental Validation of a Domestic Refrigeration Cycle
,”
ASME J. Therm. Sci. Eng. Appl.
,
14
(
7
), p.
071007
.
11.
Cheng
,
Z.
,
Zjamg
,
J.
,
Tao
,
L.
,
Chen
,
J.
,
Zheng
,
Z.
, and
Huang
,
L.
,
2025
, “
Research on Cooperative Control and Stability of Variable Refrigerant Flow Refrigeration System
,”
ASME J. Therm. Sci. Eng. Appl.
,
17
(
1
), p.
011008
.
12.
Thermodynamic Properties of Refrigerants and Refrigerant Mixtures, NIST Standard Reference Database Version 7.0, Gaithersburg, MD, 2002.
13.
ASHRAE Guidelines
,
1986
,
Engineering Analysis of Experimental Data
,
ASHRAE
,
Atlanta, GA
.
14.
Richardson
,
R. N.
, and
Butterworth
,
J. S.
,
1995
, “
The Performance of Propane/Isobutene Mixtures in a Vapour-Compression Refrigeration System
,”
Int. J. Refrig.
,
18
(
1
), pp.
58
62
.
15.
Wongwises
,
S.
,
Kamboon
,
A.
, and
Orachon
,
B.
,
2003
, “
Experimental Investigation of Hydrocarbon Mixtures to Replace HFC-134a in an Automotive Air Conditioning System
,”
Energy Convers Manage
,
47
(
11
), pp.
1644
1659
.
16.
Maclaine-Cross
,
I. L.
, and
Leonardi
,
E.
,
1997
, “
Why Hydrocarbons Save Energy?
,”
AIRAH J.
,
51
(
6
), pp.
33
37
.
You do not currently have access to this content.