Abstract

Experiments have been conducted to determine how several geometrical parameters of V-shaped porous baffles influence flow characteristics and heat transfer in a rectangular channel. Experiments were conducted on geometric parameters, namely, a relative baffle height (e/H) of 0.4–1, a relative baffle pitch (P/e) of 3–6, open area ratio values of 21–34%, and a single attack angle (α) of 60 deg. Using Reynolds numbers ranging from 2500 to 12,000, V-shaped porous baffles have been examined. Based on a relative baffle pitch of 5, a relative baffle height of 1, and an open area ratio of 21%, the maximum increases in the Nusselt number (Nu) and friction factor (f) were 2.84 and 7 times, respectively. A maximum value of 1.69 is found at e/H = 0.40, P/e = 6, and b = 34% for the thermo-hydraulic performance parameter. Correlations for (Nu) and (f) are developed as functions of P/e, e/H, and Re.

References

1.
Narinderpal
,
S. D.
,
Subhash
,
C.
, and
Saini
,
J. S.
,
2016
, “
Performance Analysis of Solar Air Heater Duct Roughened With Multi Gap V-Down Ribs Combined With Staggered Ribs
,”
Renew. Energy
,
687
(
91
), pp.
484
500
.
2.
Anil
,
K.
, and
Man-Hoe
,
K.
,
2016
, “
Thermohydraulic Performance of Rectangular Ducts With Different Multiple V-Rib Roughness Shapes: A Comprehensive Review and Comparative Study
,”
Renew. Sust. Energy Rev.
,
54
, pp.
635
652
.
3.
Giovanni
,
T.
,
2011
, “
Performance of Solar Air Heater Ducts With Different Types of Ribs on the Absorber Plate
,”
Energy
,
36
(
11
), pp.
6651
6660
.
4.
Tsay
,
Y. L.
,
Cheng
,
J. C.
, and
Chang
,
T. S.
,
2003
, “
Enhancement of Heat Transfer From Surface-Mounted Block Heat Sources in a Duct With Baffles
,”
Numer. Heat Transf.;A:Appl.
,
43
(8), pp.
827
841
.
5.
Ko
,
H.
, and
Anand
,
K.
,
2003
, “
Use of Porous Baffles to Enhance Heat Transfer in a Rectangular Channel
,”
Int. J. Heat Mass Transfer
,
46
(
22
), pp.
4191
4199
.
6.
Yeh
,
H. M.
,
Ho
,
C. D.
, and
Lin
,
C. Y.
,
2000
, “
Effect of Collector Aspect Ratio on the Collector Efficiency of Upward Type Baffled Solar Air Heaters
,”
Energy Convers. Manage.
,
41
(
9
), pp.
971
981
.
7.
Mohammadi
,
K.
, and
Sabzpooshani
,
M.
,
2013
, “
Comprehensive Performance Evaluation and Parametric Studies of Single Pass Solar Air Heater With Fins and Baffles Attached Over the Absorber Plate
,”
Energy
,
57
, pp.
741
750
.
8.
Bhandari
,
D.
, and
Singh
,
S.
,
2012
, “
Performance Analysis of Flat Plate Solar Air Collector With and Without Fins
,”
Int. J. Eng. Res. Technol.
,
1
(
6
).
9.
Gentry
,
M. C.
, and
Jacobi
,
A. M.
,
1997
, “
Heat Transfer Enhancement by Delta-Wing Vortex Generators on a Flat Plate: Vortex Interactions With the Boundary Layer
,”
Exp. Therm. Fluid. Sci.
,
14
(
3
), pp.
231
242
.
10.
Fiebig
,
M.
,
Brockmeier
,
U.
,
Mitra
,
N. K.
, and
Gütermann
,
T.
,
1989
, “
Structure of Velocity and Temperature Fields in Laminar Channel Flows With Longitudinal Vortex Generators
,”
Numer. Heat Transfer
,
15
(
3
), pp.
281
302
.
11.
Tamna
,
S.
,
Skullong
,
S.
,
Thianpong
,
C.
,
Promvonge
,
P.
,
2014
, “
Heat Transfer Behaviors in a Solar air Heater Channel With Multiple V-Baffle Vortex Generators
,”
Sol. Energy
,
110
, pp.
720
735
.
12.
Jain
,
P. K.
, and
Lanjewar
,
A.
,
2019
, “
Overview of V-Rib Geometries in Solar Air Heater and Performance Evaluation of a New V-Rib Geometry
,”
Renew. Energy
,
133
, pp.
77
90
.
13.
Alam
,
T.
,
Saini
,
R. P.
, and
Saini
,
J. S.
,
2014
, “
Experimentally Investigation on Heat Transfer Enhancement Due to V-Shaped Perforated Blocks in a Rectangular Duct of Solar Air Heater
,”
Energy Convers. Manag.
,
81
, pp.
374
383
.
14.
Alam
,
T.
,
Saini
,
R. P.
, and
Saini
,
J. S.
,
2014
, “
Effect of Circularity of Perforation Holes in V-Shaped Blockages on Heat Transfer and Friction Characteristics of Rectangular Solar Air Heater Duct
,”
Energy Convers. Manag.
,
86
, pp.
952
963
.
15.
Chamoli
,
S.
, and
Thakur
,
N. S.
,
2013
, “
Correlations for Solar Air Heater Duct With Perforated V-Shaped Baffles as Roughness Elements on Absorber Plate
,”
Int. J Sustain. Energy
,
35
(
1
), pp.
1
20
.
16.
Deo
,
N. S.
,
Chander
,
S.
, and
Saini
,
J. S.
,
2016
, “
Performance Analysis of Solar Air Heater Duct Roughened With Multigap V-Down Ribs Combined With Staggered Ribs
,”
Renew. Energy
,
91
, pp.
484
500
.
17.
Jain
,
S. K.
,
Misra
,
R.
,
Kumar
,
A.
, and
Agrawal
,
G. D.
,
2019
, “
Thermal Performance Investigation of a Solar Air Heater Having Discrete Perforated V-Shaped Baffles
,”
Int. J. Ambient Energy
,
43
(
1
), pp.
243
251
.
18.
Baissi
,
M. T.
,
Brima
,
A.
,
Aoues
,
K.
,
Khanniche
,
R.
, and
Moummi
,
N.
,
2020
, “
Thermal Behavior in a Solar Air Heater Channel Roughened With Delta-Shaped Vortex Generators
,”
Appl. Therm. Eng.
,
165
, p.
113563
.
19.
Khanlari
,
A.
,
Güler
,
,
Tuncer
,
A. D.
,
Şirin
,
C.
,
Bilge
,
Y. C.
,
Yılmaz
,
Y.
, and
Güngör
,
A.
,
2020
, “
Experimental and Numerical Study of the Effect of Integrating Plus-Shaped Perforated Baffles to Solar Air Collector in Drying Application
,”
Renew. Energy
,
145
, pp.
1677
1692
.
20.
Kumar
,
A.
,
Saini
,
R. P.
, and
Saini
,
J. S.
,
2012
, “
Experimental Investigation on Heat Transfer and Fluid Flow Characteristics of Air Flow in a Rectangular Duct With Multi V-Shaped Rib With Gap Roughness on the Heated Plate
,”
Sol. Energy
,
86
(
6
), pp.
1733
1749
.
21.
Promvonge
,
P.
,
Changcharoen
,
W.
,
Kwankaomeng
,
S.
, and
Thianpong
,
C.
,
2011
, “
Numerical Heat Transfers Study of Turbulent Square-Duct Flow Through Inline V-Shaped Discrete Ribs
,”
Int. Commun. Heat Mass Transfer
,
38
(
10
), pp.
1392
1399
.
22.
Kumar
,
R.
,
Chauhan
,
R.
,
Sethi
,
M.
, and
Kumar
,
A.
,
2017
, “
Experimental Study and Correlation Development for Nusselt Number and Friction Factor for Discretized Broken V-Pattern Baffle Solar Air Channel
,”
Exp. Therm. Fluid Sci.
,
81
, pp.
56
75
.
23.
Kumar
,
R.
,
Kumar
,
A.
,
Sharma
,
A.
,
Chauhan
,
R.
, and
Sethi
,
M.
,
2016
, “
Experimental Study of Transfer Enhancement in Rectangular Duct Distributed by Multi-V-Perforated Baffle Different Relative Baffle Width
,”
Heat Mass Transfer
,
539
(
4
), pp.
1289
1304
.
24.
Kumar
,
R.
,
Kumar
,
A.
,
Chauhan
,
R.
, and
Maithani
,
R.
,
2018
, “
Comparative Study of Effect of Various Blockage Arrangements on Thermal Hydraulic Performance in a Roughened Air Passage
,”
Renewable Sustainable Energy Rev.
,
81
, pp.
447
463
.
25.
Kumar
,
A.
, and
Layek
,
A.
,
2020
, “
Nusselt Number and Friction Factor Correlation of Solar Air Heater Having Winglet Type Vortex Generator Over Absorber Plate
,”
Sol. Energy
,
205
, pp.
334
348
.
26.
Li
,
J. L.
,
Tang
,
H. W.
, and
Yang
,
Y. T.
,
2018
, “
Numerical Simulation and Thermal Performance Optimization of Turbulent Flow in a Channel With Multi-V-Shaped Baffles
,”
Int. Comm. Heat Mass Transf.
,
92
, pp.
39
50
.
27.
Hans
,
V. S.
,
Saini
,
R. P.
, and
Saini
,
J. S.
,
2010
, “
Heat Transfer and Friction Factor Correlations for a Solar Air Heater Duct Roughened Artificially With Multiple V-Ribs
,”
Sol. Energy
,
84
(
6
), pp.
898
911
.
28.
Promvonge
,
P.
,
2010
, “
Heat Transfer and Pressure Drop in a Channel With Multiple 60 Deg V-Baffles
,”
Int. Commun. Heat Mass Transfer
,
37
(
7
), pp.
835
840
.
29.
Promvonge
,
P.
,
Jedsadaratanachai
,
W.
,
Kwankaomeng
,
S.
, and
Thianpong
,
C.
,
2012
, “
3D Simulation of Laminar Flow and Heat Transfer in V-Baffled Square Channel
,”
Int. Commun. Heat Mass Transf.
,
39
(
1
), pp.
85
93
.
30.
Karmare
,
S. V.
, and
Tikekar
,
A. N.
,
2010
, “
Analysis of Fluid Flow and Heat Transfer in a Rib Grit Roughened Surface Solar Air Heater Using CFD
,”
Sol. Energy
,
84
(
3
), pp.
409
417
.
31.
ASHRAE Standard 93-77
,
1977
,
Method of Testing to Determine the Thermal Performance of Solar Air Heater
,
New York
. https://ashrae.iwrapper.com/ViewOnLine/Standard_93–1977.
32.
Webb
,
R. L.
, and
Eckert
,
E. R. G.
,
1972
, “
Application of Rough Surfaces to Heat Exchanger Design
,”
Int. J. Heat Mass Transf.
,
15
(
9
), pp.
1647
1658
.
33.
Kline
,
S. J.
, and
McClintock
,
F. A.
,
1953
, “
Describe Uncertainties in Single Sample Experiments
,”
Mech. Eng.
,
75
, pp.
3
8
.
34.
Rosenhow
,
W. M.
, and
Hartnett
,
J. P.
,
1973
,
Hand Book of Heat Transfer
,
Mc Graw-Hill
,
New York
.
35.
Kakac
,
S.
,
Shah
,
R. K.
, and
Aung
,
W.
,
1987
,
Hand Book of Single-Phase Convective Heat Transfer
,
Wiley
,
New York
.
36.
Molki
,
M.
, and
Esfahanian
,
A. H.
,
1992
, “
Turbulent Convective Mass Transfer Downstream of a Perforated Baffle Blockage
,”
Int. J. Heat Fluid Flow
,
13
(
2
), pp.
116
123
.
37.
El Habet
,
M. A.
,
Ahmed
,
S. A.
, and
Saleh
,
M. A.
,
2022
, “
The Effect of Using Staggered and Partially Tilted Perforated Baffles on Heat Transfer and Flow Characteristics in a Rectangular Channel
,”
Int. J. Therm. Sci.
,
174
, p.
107422
.
38.
El Habet
,
M. A.
,
Ahmed
,
S. A.
, and
Saleh
,
M. A.
,
2021
, “
Thermal/Hydraulic Characteristics of a Rectangular Channel With Inline/Staggered Perforated Baffles
,”
Int. Commun. Heat Mass Transfer
,
128
, p.
105591
.
39.
Karwa
,
R.
, and
Maheshwari
,
B. K.
,
2009
, “
Heat Transfer and Friction in an Asymmetrically Heated Rectangular Channel With Half and Fully Perforated Baffles at Different Pitches
,”
Int. Commun. Heat Mass
,
36
(
3
), pp.
264
268
.
40.
Shin
,
S.
, and
Kwak
,
J. S.
,
2008
, “
Effect of Hole Shape on the Heat Transfer in a Rectangular Duct With Perforated Blockage Walls
,”
J. Mech. Sci. Technol.
,
22
(
10
), pp.
1945
1951
.
You do not currently have access to this content.