Abstract

In case of an emergency in an underground coal mine, miners who fail to escape from the mine can enter a refuge alternative (RA) for protection from adverse conditions, such as high carbon monoxide levels. One of the main concerns with the use of both portable and built-in-place (BIP) RAs, especially for hot or deep mines, is the interior temperature rise due to the occupants' metabolic heat and the heat released by devices such as the carbon dioxide (CO2) scrubbing system. The humidity within the RA will also increase through occupants' respiration and perspiration and from the chemical reaction within the CO2 scrubbing system. Heat and humidity buildup can subject the occupants to hazardous thermal conditions. To protect RA occupants, Mine Safety and Health Administration regulations mandate a maximum apparent temperature of 95 °F within an occupied RA. The National Institute for Occupational Safety and Health (NIOSH) tested both an air-conditioned borehole air supply (BAS) and a cryogenic air supply for RAs in the NIOSH Experimental Mine in Bruceton, PA. The BAS was tested on a 60-person BIP RA, while the cryogenic air supply was tested on a 30-person BIP RA and a portable 23-person tent-type RA. Multiple tests were conducted with both air supplies to assess their ability to cool RAs. The test results show that the BAS and the cryogenic air supply were able to maintain the apparent temperature within the tested RAs under the 95 °F limit. The BAS and the cryogenic air supply are potential RA heat mitigation strategies that mines could use to prevent heat/humidity buildup within RAs.

References

1.
Klein
,
M.
,
Yantek
,
D.
, and
Hepokoski
,
M. A. Y. L.
,
2017
, “
Prediction of Human Core Temperature Rise and Moisture Loss in Refuge Alternatives for Underground Coal Mines
,”
Trans. Soc. Min. Metall. Explor.
,
342
(
1
), pp.
29
35
.
2.
Bernard
,
T.
,
Yantek
,
D.
, and
Thimons
,
E.
,
2018
, “
Estimation of Metabolic Heat Input for Refuge Alternative Thermal Testing and Simulation
,”
Min. Eng.
,
70
(
8
), pp.
50
54
.
3.
MSHA
,
2008
, “
30 CFR Parts 7 and 75; Refuge Alternatives for Underground Coal Mines; Final Rule
,”
U.S. Department of Labor, Mine Safety and Health Administration
.
4.
MSHA
,
2014
, “
30 CFR Part 7: Testing, Evaluation, and Approval of Mining Products
,”
U.S. Department of Labor, Mine Safety and Health Administration
.
5.
Yan
,
L.
,
Yantek
,
D.
,
Reyes
,
M.
,
Damiano
,
N.
,
Srednicki
,
J.
,
Bickson
,
J.
, and
Whisner
,
B.
,
2018
, “
Cooling Systems for Refuge Alternatives in Hot Mine Conditions
,”
ASME 2018 International Mechanical Engineering Congress and Exposition
,
Pittsburgh, PA
,
Nov. 9–15
, Paper No. IMECE2018-87507.
6.
Wu
,
B.
,
Lei
,
B.
,
Zhou
,
C.
, and
Zhao
,
Z.
,
2012
, “
Experimental Study of Phase Change Material’s Application in Refuge Chamber of Coal Mine
,”
Procedia Eng.
,
45
(
1
), pp.
936
941
.
7.
Wang
,
S.
,
Jin
,
L.
,
Han
,
Z.
,
Li
,
Y.
,
Ou
,
S.
,
Gao
,
N.
, and
Huang
,
Z.
,
2017
, “
Discharging Performance of a Forced-Circulation Ice Thermal Storage System for a Permanent Refuge Chamber in an Underground Mine
,”
Appl. Therm. Eng.
,
110
(
1
), pp.
703
709
.
8.
Xu
,
X.
,
You
,
S.
,
Zheng
,
X.
,
Zhang
,
H.
, and
Liu
,
S.
,
2017
, “
Cooling Performance of Encapsulated Ice Plates Used for the Underground Refuge Chamber
,”
Appl. Therm. Eng.
,
112
(
1
), pp.
259
272
.
9.
Yantek
,
D.
,
2014
, “
Investigation of Temperature Rise in Mobile Refuge Alternatives
,”
U.S. Department of Health and Human Services, Centers for Disease Control and Prevention, National Institute for Occupational Safety and Health, Office of Mine Safety and Health Research
.
10.
Yan
,
L.
,
Yantek
,
D.
,
Klein
,
M.
,
Bissert
,
P.
, and
Matetic
,
R.
,
2016
, “
Validation of Temperature and Humidity Thermal Model of 23-Person Tent-Type Refuge Alternative
,”
Min. Eng. Mag.
,
68
(
9
), pp.
97
103
.
You do not currently have access to this content.