The objective of the experiments was to quantify how attic ventilation would affect the performance of a radiant barrier. Ceiling heat flux and space cooling load were both measured. Results of side-by-side radiant barrier experiments using two identical 13.38 m2 (nominal) test houses are presented. The test houses responded similarly to weather variations. Indoor temperatures of the test houses were controlled to within 0.2°C. Ceiling heat fluxes and space cooling load were within a 2.5 percent difference between both test houses. The results showed that a critical attic ventilation flow rate of 1.3 (l/sec)/m2 of the attic floor existed after which the percentage reduction in ceiling heat fluxes produced by the radiant barriers did not change with increasing attic airflow rates. The ceiling heat flux reductions produced by the radiant barriers were between 25 and 35 percent, with 28 percent being the percent reduction observed most often in the presence of attic ventilation. The space-cooling load reductions observed were between two to four percent. All results compiled in this paper were for attics with unfaced fiberglass insulation with a resistance level of 3.35 m2 K/W (nominal) and for a perforated radiant barrier with low emissivities (less than 0.05) on both sides.
Skip Nav Destination
Article navigation
November 1992
Research Papers
Effect of Attic Ventilation on the Performance of Radiant Barriers
Mario A. Medina,
Mario A. Medina
Department of Mechanical Engineering, Texas A&M University, College Station, TX 77843
Search for other works by this author on:
Dennis L. O’Neal,
Dennis L. O’Neal
Department of Mechanical Engineering, Texas A&M University, College Station, TX 77843
Search for other works by this author on:
W. Dan Turner
W. Dan Turner
College of Engineering, Texas A&M University, College Station, TX 77843
Search for other works by this author on:
Mario A. Medina
Department of Mechanical Engineering, Texas A&M University, College Station, TX 77843
Dennis L. O’Neal
Department of Mechanical Engineering, Texas A&M University, College Station, TX 77843
W. Dan Turner
College of Engineering, Texas A&M University, College Station, TX 77843
J. Sol. Energy Eng. Nov 1992, 114(4): 234-239 (6 pages)
Published Online: November 1, 1992
Article history
Received:
November 2, 1991
Revised:
May 11, 1992
Online:
June 6, 2008
Citation
Medina, M. A., O’Neal, D. L., and Turner, W. D. (November 1, 1992). "Effect of Attic Ventilation on the Performance of Radiant Barriers." ASME. J. Sol. Energy Eng. November 1992; 114(4): 234–239. https://doi.org/10.1115/1.2930011
Download citation file:
Get Email Alerts
Assessment of Particle Candidates for Falling Particle Receiver Applications Through Irradiance and Thermal Cycling
J. Sol. Energy Eng (June 2025)
Linear Fresnel Reflector Power Plants in Algeria: Energy, Economic, and Environmental Analysis
J. Sol. Energy Eng (June 2025)
Modeling and Simulation of Solar Compound Parabolic Concentrator-Integrated Low-Temperature Thermal Desalination System
J. Sol. Energy Eng (June 2025)
Annual Energy Analysis of a Building-Integrated Semitransparent Photovoltaic Thermal Façade
J. Sol. Energy Eng (June 2025)
Related Articles
Experimental and Numerical Investigation of Forced Convective Characteristics of Arrays of Channel Mounted Obstacles
J. Heat Transfer (February,1999)
A Transient Heat and Mass Transfer Model of Residential Attics Used to Simulate Radiant Barrier Retrofits, Part II: Validation and Simulations
J. Sol. Energy Eng (February,1998)
Reducing the Natural Convection Inside an Enclosure Using a Concentric Internal Open Square
J. Heat Transfer (April,2022)
Airflow and Air Quality in a Large Enclosure
J. Sol. Energy Eng (May,1995)
Related Proceedings Papers
Related Chapters
Human Perception Relations Between Air Movement Perception Acceptability and Preference for Ceiling Mounted Personalized Ventilation System
International Conference on Green Buildings and Optimization Design (GBOD 2012)
Interaction of Dynamic Indoor Environment with Moving Person and Performance of Ceiling Mounted Personalized Ventilation System
International Conference on Green Buildings and Optimization Design (GBOD 2012)
Control and Operational Performance
Closed-Cycle Gas Turbines: Operating Experience and Future Potential