Abstract

The causes of roof damage found on a large-scale water storage tank were investigated using hydrodynamic analysis. All operation and weather data, such as temperature inside and outside of the storage tank, atmospheric pressure, water level according to time, condensed water check inside pipelines, snowfall, and wind speed, were precisely reviewed. Four potential scenarios were postulated to estimate the vacuum pressure, presumed to be a direct cause of the roof damage to the storage tank. In the scenarios, an energy equation with a friction loss for pipelines and fittings was adopted to compute the pressure differences between the inlet and outlet of the ventilation and overflow pipes. A timewise pressure drop for the condition of fully clogged connected lines during a discharge operation was also carried out. A sequence solution for the unsteady Bernoulli equation to represent the dynamic motion of a water column inside a loop seal was successfully derived. This can predict the vacuum pressure limit inside the storage tank required to drain out the water from the loop seal. The predicted vacuum pressure was compared with the vacuum pressure required to cause the buckling phenomena at the roof support structures. In-depth analysis of each scenario showed that the roof damage of the storage tank developed when the vacuum pressure reached over the estimated vacuum pressure limit. To prevent further roof damage, including the storage tank of the same design at other plant, change of the layout of the air ventilation line was recommended.

References

1.
Chang
,
J. I.
, and
Lin
,
C.-C.
,
2006
, “
A Study of Storage Tank Accidents
,”
J. Loss Prev. Process Ind.
,
19
(
1
), pp.
51
59
.10.1016/j.jlp.2005.05.015
2.
Godoy
,
L. A.
,
2016
, “
Buckling of Vertical Oil Storage Steel Tanks: Review of Static Buckling Studies
,”
Thin-Walled Struct.
,
103
, pp.
1
21
.10.1016/j.tws.2016.01.026
3.
de Paor
,
C.
,
Kelliher
,
D.
,
Cronin
,
K.
,
Wright
,
W. M. D.
, and
McSweeney
,
S. G.
,
2012
, “
Prediction of Vacuum-Induced Buckling Pressures of Thin-Walled Cylinders
,”
Thin-Walled Struct.
,
55
, pp.
1
10
.10.1016/j.tws.2012.03.001
4.
Kim
,
W. B.
,
Suh
,
Y. P.
,
Park
,
C. Y.
, and
Ryu
,
K. W.
,
1998
, “
Analysis of the Damage Source for the Roof of the Raw Water Storage Tank at Ilsan Combined Cycle Powerplant (Korean)
,” Technical Memorandum, Korea Electric Power Research Institute, Daejeon, South Korea, Report No. TM.C97MS01.S1998.416.
5.
API
,
1988
, “Welded Steel Tanks for Oil Storage,” 8th ed.,
American Petroleum Institute
,
Washington, DC
, Standard No. API-650-1988.
6.
Sanders
,
R. E.
,
1999
,
Chemical Process Safety, Learning From Case Histories
, 3rd ed.,
Elsevier Butterworth-Heinemann
,
Oxford, UK
.
7.
Kletz
,
T.
,
2009
,
What Went Wrong?—Case Histories of Process Plant Disasters and How They Have Been Avoided
, 5th ed.,
Elsevier Butterworth-Heinemann/IChemE
,
Oxford, UK
.
8.
Griffin
,
M. L.
,
2000
, “
Protecting Atmospheric Storage Tanks Against Vacuum Collapse
,”
J. Loss Prev. Process Ind.
,
13
(
2
), pp.
83
89
.10.1016/S0950-4230(99)00074-1
9.
Trevuna
,
F.
,
Simcak
,
F.
, and
Bocko
,
J.
,
2009
, “
Failure Analysis of Storage Tank
,”
Eng. Failure Anal.
,
16
(
1
), pp.
26
38
.10.1016/j.engfailanal.2007.12.005
10.
Sabersky
,
R. H.
,
Acosta
,
A. J.
,
Hauptmann
,
E. G.
, and
Gates
,
E. M.
,
1999
,
Fluid Flow, a First Course in Fluid Mechanics
, 4th ed.,
Prentice Hall
,
New Jersey
.
11.
Crane Company Engineering Department
,
2009
,
Flow of Fluids: Through Valves, Fittings and Pipe
,
Crane
,
Stamford, CT
.
12.
Park
,
D. S.
,
2013
, “
Prediction of Vacuum Pressures to Induce Roof Deformation of Hold-Up Tank Using FEM Analysis
,” Presentation Contents at Investigation Board, Busan, South Korea, Feb. 6, pp.
1
10
.
You do not currently have access to this content.