Abstract

Inside the brain tumor, the blood vessels are intricately composed, and the tumors and blood vessels are similar in color. Therefore, when observing tumors and blood vessels with the naked eye or a surgical microscope, it is difficult to distinguish between tumors and blood vessels. Fluorescence staining with indocyanine green (ICG) is performed to distinguish between brain tumors and blood vessels using a surgical microscope. However, when observing the blood circulation state of a tumor or blood vessel through a surgical microscope, light reflection occurs from the camera. In the process of observing the state of the blood vessel, due to the occurrence of light reflection, an obstruction phenomenon in which the observation field is blocked by the blood vessel of the object to be observed occurs. Therefore, it is difficult to diagnose the vascular condition. In this experiment, the 780 nm light-emitting diode (LED) was irradiated to the ICG phantom, and then, when the fluorescence expression image was observed, the polarizing filter such as circular polarized light (CPL) filter and linear polarized light (LPL) filter was inserted into the camera, and the reflected light was reduced. Therefore, it is possible to reduce the reflected light from the fluorescence expression image by using a polarizing filter, and it is expected to be applicable to surgery and diagnostic fields of cancer such as surgery.

References

1.
World Health Organisation (WHO)
,
2021
, “
Cancer, Newsroom/Fact Sheets/Detail/Cancer
,” World Health Organisation, Geneva, Switzerland, accessed Sept. 21, 2021, https://www.who.int/news-room/fact-sheets/detail/cancer
2.
Lefranc
,
F.
,
Sadeghi
,
N.
,
Camby
,
I.
,
Metens
,
T.
,
Dewitte
,
O.
, and
Kiss
,
R.
,
2006
, “
Present and Potential Future Issues in Glioblastoma Treatment
,”
Expert Rev. Anticancer Ther.
,
6
(
5
), pp.
719
732
.10.1586/14737140.6.5.719
3.
Yoon
,
W. B.
,
Kim
,
H. R.
,
Lee
,
H. M.
,
Kim
,
Y. J.
,
Kim
,
K. G.
,
Yoo
,
H.
, and
Lee
,
S. H.
,
2015
, “
Development of Image-Based System for Multiple Fluorescence Imaging Study
,”
J. Korea Multimedia Soc.
,
18
(
12
), pp.
1445
1452
.10.9717/kmms.2015.18.12.1445
4.
Lee
,
D. H.
,
Jo
,
M. W.
,
Choi
,
J. S.
, and
Kim
,
H. C.
,
2014
, “
A Robust Algorithm Tracking on Endoscopic Images in Robot-Assisted Surgery
,”
Proceedings of the Society of CAD/CAM Engineers
, Jerusalem, Israel, Oct. 9–13, pp.
326
330
.
5.
Yu
,
X. J.
, and
Kwok
,
H. S.
,
2003
, “
Optical Wire-Grid Polarizers at Oblique Angles of Incidence
,”
J. Appl. Phys.
,
93
(
8
), pp.
4407
4412
.10.1063/1.1559937
6.
Paul Peter Urone
,
P. P.
,
Sharma
,
M.
,
Dirks
,
K.
, and
Sharma
,
M.
,
2012
, “
College Physics
,” XanEdu, Chapter Polarization 27.8 to 27.9, Chicago, IL.
7.
Saleh
,
B. E. A.
, and
Teich
,
M. C.
,
2007
,
Fundamentals of Photonics
, 2nd ed., Chap. 6.1 to 6.2,
Wiley and Sons
,
New York
, pp.
195
203
.
8.
Valli
,
D.
,
Belykh
,
E.
,
Zhao
,
X.
,
Gandhi
,
S.
,
Cavallo
,
C.
,
Martirosyan
,
N. L.
,
Nakaji
,
P.
,
Lawton
,
M. T.
, and
Preul
,
M. C.
,
2019
, “
Development of a Simulation Model for Fluorescence-Guided Brain Tumor Surgery
,”
Front. Oncol.
,
9
(
9
), p.
748
.10.3389/fonc.2019.00748
9.
Chiou
,
T. H.
,
Kleinlogel
,
S.
,
Cronin
,
T.
,
Caldwell
,
R.
,
Loeffler
,
B.
,
Siddiqi
,
A.
,
Goldizen
,
A.
, and
Marshall
,
J.
,
2008
, “
Circular Polarization Vision in a Stomatopod Crustacean
,”
Curr. Biol.
,
18
(
6
), pp.
429
434
.10.1016/j.cub.2008.02.066
10.
Understanding of Physics
, 2021, “
Double Refraction
,” Understanding of Physics, accessed Nov. 18, 2021, http://physica.gsnu.ac.kr/phtml/optics/polarization/birefringence/birefringence5.html
11.
Kim
,
Y. J.
,
Lee
,
D. A.
,
Yoon
,
K. C.
, and
Kim
,
K. G.
,
2019
, “
Concentration Range Analysis for Fluorescence Expression of Indocyanine Green
,”
Korea Multimedia Soc.
,
22
(
12
), pp.
1339
1346
.10.9717/kmms.2019.22.12.1339
12.
Shen
,
L.
,
1981
, “
The Elliptical Microstrip Antenna With Circular Polarization
,”
IEEE Trans. Antennas Prop.
,
29
(
1
), pp.
90
94
.10.1109/TAP.1981.1142545
13.
Lumenera
,
2021
, “
LT225
,” Teledyne Lumenera, Ottawa, ON, Canada, accessed Nov. 18, 2021, https://www.lumenera.com/lt225.html
14.
Thorlabs
,
2021
, “
M780L3
,” Thorlabs, Newton, NJ, accessed Nov. 18, 2021, https://www.thorlabs.com/search/thorsearch.cfm?search=M780L3
15.
Choi
,
H. J.
,
Hwang
,
N.
,
Yoon
,
K. C.
,
Kim
,
E.
, and
Kim
,
K. G.
,
2018
, “
Manufacturing Method of Vein Phantom for Reuse of the Indocyanine Green Fluorescein Material
,”
Int. Soc. Med. Innov. Technol.
, pp.
509
512
.
16.
Chen
,
C. Y.
,
Hwang
,
R. C.
, and
Chen
,
Y. J.
,
2010
, “
A Passive Auto-Focus Camera Control System
,”
Appl. Soft Comput. J.
,
10
(
1
), pp.
296
303
.10.1016/j.asoc.2009.07.007
You do not currently have access to this content.