Herein we present a new helical slit tip for the nasogastric (NG) tube to reduce clogging, as well as an accompanying modular in-line flusher to simplify flow restoration to a clogged tube. Nasogastric tubes are one of the most ubiquitous medical devices used in urgent and intensive care situations. Most commonly used to evacuate the stomach during cases of small obstructive bowel syndrome and surgical operations, the NG tube is prone to clogging. A detailed analysis of nasogastric tube obstruction in an ex vivo model was performed. The proposed NG tube tip is an improvement over the current state of the art. Clogging by suction to the mucosa is prevented by the continuous and helical nature of the suction area. Clogging by food particles is avoided by introducing slits rather than holes, and thus inhibiting close packing and clogging of the particulate on the suction tip. The modular in-line flusher is a device that combines into one push the many steps a caregiver usually takes to unclog the tube via flushing, with no disconnections required. Use of the redesigned NG tube and modular in-line flusher will reduce the need to troubleshoot and replace NG tubes, saving care providers’ time, reducing hospital costs, and reducing patient discomfort.
Skip Nav Destination
Article navigation
Design Of Medical Devices Conference Abstracts
Nasogastric Tube Design to Reduce Clogging and Simplify Flushing
James A. Ankrum,
James A. Ankrum
Massachusetts Institute of Technology
Search for other works by this author on:
Alison Olechowski,
Alison Olechowski
Massachusetts Institute of Technology
Search for other works by this author on:
Jose A. Canseco,
Jose A. Canseco
Massachusetts Institute of Technology
Search for other works by this author on:
Elliot Greenblatt,
Elliot Greenblatt
Massachusetts Institute of Technology
Search for other works by this author on:
Michael P. Roberts,
Michael P. Roberts
Massachusetts Institute of Technology
Search for other works by this author on:
Nevan C. Hanumara,
Nevan C. Hanumara
Massachusetts Institute of Technology
Search for other works by this author on:
Alexander H. Slocum
Alexander H. Slocum
Massachusetts Institute of Technology
Search for other works by this author on:
James A. Ankrum
Massachusetts Institute of Technology
Alison Olechowski
Massachusetts Institute of Technology
Jose A. Canseco
Massachusetts Institute of Technology
Elliot Greenblatt
Massachusetts Institute of Technology
Michael P. Roberts
Massachusetts Institute of Technology
Nevan C. Hanumara
Massachusetts Institute of Technology
Alexander H. Slocum
Massachusetts Institute of Technology
J. Med. Devices. Jun 2011, 5(2): 027510 (1 pages)
Published Online: June 9, 2011
Article history
Online:
June 9, 2011
Published:
June 9, 2011
Citation
Ankrum, J. A., Olechowski, A., Canseco, J. A., Greenblatt, E., Roberts, M. P., Hanumara, N. C., and Slocum, A. H. (June 9, 2011). "Nasogastric Tube Design to Reduce Clogging and Simplify Flushing." ASME. J. Med. Devices. June 2011; 5(2): 027510. https://doi.org/10.1115/1.3589815
Download citation file:
Get Email Alerts
Cited By
Related Articles
Introduction
J. Med. Devices (June,2011)
Proposed Protocol for Objective Morcellator Analysis
J. Med. Devices (June,2011)
Design and Development of an Improved Tissue Retractor for Use in Minimally Invasive Surgical Procedures
J. Med. Devices (June,2011)
Vaginal Approach for Uterus Separation During Laparoscopic Hysterectomy
J. Med. Devices (June,2010)
Related Proceedings Papers
Related Chapters
Heat Generated in Pipe Flows Due to Friction
Everyday Heat Transfer Problems: Sensitivities to Governing Variables
Neural Network and Genetic Programming in Pressure Loss Estimation in Eccentric Pipe Flow
Intelligent Engineering Systems through Artificial Neural Networks Volume 18
Spherical SOFM: Implications for Forensics and Craniofacial Surgery
Intelligent Engineering Systems through Artificial Neural Networks