Laparascopic surgery required inducing a pneumoperitoneum during surgery and anesthesia this presents unique hemodynamic challenges for the anesthetic management of patients. We monitored hemodynamic management using ECOM endotracheal tubes the parameters are derived using Bioimpedance Cardiac output, stroke volume variability, and systemic vascular resistance were measured using this technology. Pneumoperitoneum results in intra-abdominal pressure of 15–20 mm hg induced by insufflation Hemodynamic parameters were measured using a new noninvasive device, the endotracheal cardiac output monitor (ECOM) (ConMed Corporation, Utica, NY). This monitor provides measurements—including cardiac output, systemic vascular resistance, and stroke volume variation—which were previously unavailable noninvasively. The results obtained were consistent with those found in the literature (1–4). Based on our assessment, it appears that ECOM derived hemodynamic changes are similar to those obtained invasively. Therefore, ECOM’s noninvasive method to measure cardiac output seems advantageous when considering patient safety, because it is less invasive. A better understanding of the applicability and reliability of this new technology in the clinical setting is important for patient safety.
Skip Nav Destination
Article navigation
Design Of Medical Devices Conference Abstracts
Hemodynamic Changes Induced by Pneumoperitoneum and Measured With ECOM
Booyeon Han
Booyeon Han
Princeton University
Search for other works by this author on:
Timothy Shine
Mayo Clinic
David Corda
Mayo Clinic
Stephen Aniskevich
Mayo Clinic
Bruce Leone
Mayo Clinic
Neil Feinglass
Mayo Clinic
Sorin Brull
Mayo Clinic
Booyeon Han
Princeton University
J. Med. Devices. Jun 2011, 5(2): 027504 (1 pages)
Published Online: June 3, 2011
Article history
Published:
June 1, 2011
Online:
June 3, 2011
Citation
Shine, T., Corda, D., Aniskevich, S., Leone, B., Feinglass, N., Brull, S., and Han, B. (June 3, 2011). "Hemodynamic Changes Induced by Pneumoperitoneum and Measured With ECOM." ASME. J. Med. Devices. June 2011; 5(2): 027504. https://doi.org/10.1115/1.3589225
Download citation file:
1,255
Views
Get Email Alerts
Cited By
A Better Way to Visualize the Cervix: A Low-Cost Cervical Cancer Screening Device for LMIC Settings
J. Med. Devices (April 2025)
Comparative Survey-Based Study of Noninvasive Saliva Collection Devices
J. Med. Devices (April 2025)
Related Articles
Cerebrospinal Fluid Volume Monitoring for Hydrocephalus Therapy
J. Med. Devices (June,2011)
Designing an Optical Bendloss Sensor for Clinical ForcMeasurement
J. Med. Devices (June,2009)
Recumbent Exercise Bicycle for Low-Impact Rehabilitation of Obese Individuals
J. Med. Devices (June,2009)
A Minimally Invasive Device for Continuous Glucose Monitoring in Infants
J. Med. Devices (June,2008)
Related Proceedings Papers
Related Chapters
Conclusions and future perspectives
Impedimetric Biosensors for Medical Applications: Current Progress and Challenges
Introduction
Modified Detrended Fluctuation Analysis (mDFA)
mDFA Empirical Results
Modified Detrended Fluctuation Analysis (mDFA)