In this paper we detail the rapid design, fabrication and testing of a percutaneous catheterbased device that is envisioned to enable externally controlled manipulation and cutting of specific chordae tendinae within the heart. The importance of this work is that it (a) provides a means that surgeons may use to alleviate problems associated with some forms of mitral valve regurgitation and (b) demonstrates how a deterministic design process may be used to drive design innovation in medical devices while lowering development cost/time/resources. In the United States alone, approximately 500,000 people develop ischemic or functional MR per year. A chordal cutting procedure and device could allow many patients, who would otherwise be unable to survive open-heart surgery, to undergo a potentially life-saving operation at reduced risk. The design process has enabled us to generate a solution to this problem in a relatively short time. A deterministic design process was used to generate several design concepts and then evaluate and compare each concept based on a set of functional requirements. A final concept to be alpha prototyped was then chosen, optimized, and fabricated. The design process made it possible to make rapid progress during the project and to achieve a device design that worked the first time. This approach is important to medical device design as it reduces engineering effort, cost, and the amount of time spent in iterative design cycles. An overview of the design process will be presented and discussed within the context of a specific case study–the rapid design/fabrication of a chordal cutting device. Experimental results will be used to assess: (i) The performance of the catheter in maneuvering into the heart and grasping various structures. (ii) The effectiveness of the catheter's RF ablation tip at cutting chordae inside of a heart. In the first experiment, the catheter was guided to the basal chordae under direct visualization, which showed that the catheter is capable of successfully grasping a chord. During the second experiment, ultrasound was shown to be a viable method of visualizing the catheter within the heart. During this experiment, once contact between the chord and RF ablator tip was confirmed, the chord was successfully ablated. We will also discuss experiments that are currently underway to visualize the catheter utilizing a Trans-Esophageal Echo probe, as well as imaging the mitral valve from the apex of the heart with a laparoscope so that video of the basal chord being grasped and cut can be acquired on a heart whose anatomical structures are intact. A brief synopsis will then be given of how the design process has been used in research and educational collaborations between MIT and local hospitals.
Skip Nav Destination
Article navigation
Design Of Medical Devices Conference Abstracts
Design of a Catheter-Based Device for Performing Percutaneous Chordal-Cutting Procedures
A. H. Slocum, Jr.,
A. H. Slocum, Jr.
Massachusetts Institute of Technology
, Department of Mechanical Engineering Cambridge, MA
Search for other works by this author on:
A. H. Slocum, Jr.
Massachusetts Institute of Technology
, Department of Mechanical Engineering Cambridge, MAJ. Med. Devices. Jun 2009, 3(2): 027542 (1 pages)
Published Online: July 24, 2009
Article history
Published:
July 24, 2009
Citation
Slocum, A. H., Jr., Bosworth, W. R., Mazumdar, A., Saez, M. A., Culpepper, M. L., and Levine, R. A., MD (July 24, 2009). "Design of a Catheter-Based Device for Performing Percutaneous Chordal-Cutting Procedures." ASME. J. Med. Devices. June 2009; 3(2): 027542. https://doi.org/10.1115/1.3134783
Download citation file:
1,324
Views
Get Email Alerts
Cited By
Related Articles
Design of a Motion Compensated Tissue Resection Catheter for Beating Heart Cardiac Surgery
J. Med. Devices (June,2011)
Design of a Novel Experimental Setup for the Assessment of the Fossa Ovalis Within Large Mammalian Hearts: Investigating Tissue Properties and Clinical Devices Used for Transseptal Access
J. Med. Devices (June,2011)
CT Visualization of Cryoablation in Pulmonary Veins
J. Med. Devices (June,2009)
Design of an Autoclavable Active Cannula Deployment Device
J. Med. Devices (June,2011)
Related Chapters
Spherical SOFM: Implications for Forensics and Craniofacial Surgery
Intelligent Engineering Systems through Artificial Neural Networks
mDFA Human Empirical Results
Modified Detrended Fluctuation Analysis (mDFA)
Introduction and scope
Impedimetric Biosensors for Medical Applications: Current Progress and Challenges