This article studies the design of passive elastic elements to reduce the actuator requirements for powered ankle prostheses. The challenge is to achieve most of the typically nonlinear ankle response with the passive element so that the active ankle-torque from the actuator can be small. The main contribution of this article is the design of a cam-based lower-limb prosthesis to achieve such a nonlinear ankle response. Results are presented to show that the addition of the cam-based passive element can reduce the peak actuator torque requirement substantially, by ∼74%. Moreover, experimental results are presented to demonstrate that the cam-based design can achieve a desired nonlinear response to within 10%.

References

1.
U.S. Bureau of the Census
,
1995
,
Statistical Abstract of the United States
, 115th ed., U.S. Bureau of the Census,
Washington, DC
, p.
145
.
2.
Fletcher
,
D. D.
,
Andrews
,
K.
,
Hallett
,
J.
,
Butters
,
M.
,
Rowland
,
C.
, and
Jacobsen
,
S.
,
2002
, “
Trends in Rehabilitation After Amputation for Geriatric Patients With Vascular Disease: Implications for Future Health Resource Allocation
,”
Arch. Phys. Med. Rehabil.
,
83
(
10
), pp.
1389
1393
.10.1053/apmr.2002.34605
3.
Sun
,
J.
, and
Voglewede
,
P. A.
,
2013
, “
Powered Transtibial Prosthetic Device Control System Design, Implementation, and Bench Testing
,”
ASME J. Med. Devices
,
8
(
1
), p.
011004
.10.1115/1.4025851
4.
Versluys
,
R.
,
Beyl
,
P.
,
Van Damme
,
M.
,
Desomer
,
A.
,
Van Ham
,
R.
, and
Lefeber
,
D.
,
2009
, “
Prosthetic Feet: State-of-the-Art Review and the Importance of Mimicking Human Ankle-Foot Biomechanics
,”
Disability Rehabil. Assistive Technol.
,
4
(
2
), pp.
65
75
.10.1080/17483100802715092
5.
Morgenroth
,
D. C.
,
Segal
,
A. D.
,
Zelik
,
K. E.
,
Czerniecki
,
J. M.
,
Klute
,
G. K.
,
Adamczyk
,
P. G.
,
Orendurff
,
M. S.
,
Hahn
,
M. E.
,
Collins
,
S. H.
, and
Kuo
,
A. D.
,
2011
, “
The Effect of Prosthetic Foot Push-Off on Mechanical Loading Associated With Knee Osteoarthritis in Lower Extremity Amputees
,”
Gait Posture
,
34
(
4
), pp.
502
507
.10.1016/j.gaitpost.2011.07.001
6.
Segal
,
A. D.
,
Zelik
,
K. E.
,
Klute
,
G. K.
,
Morgenroth
,
D. C.
,
Hahn
,
M. E.
,
Orendurff
,
M. S.
,
Adamczyk
,
P. G.
,
Collins
,
S. H.
,
Kuo
,
A. D.
, and
Czerniecki
,
J. M.
,
2012
, “
The Effects of a Controlled Energy Storage and Return Prototype Prosthetic Foot on Transtibial Amputee Ambulation
,”
Hum. Mov. Sci.
,
31
(
4
), pp.
918
931
.10.1016/j.humov.2011.08.005
7.
Hansen
,
A. H.
,
Childress
,
D. S.
,
Miff
,
S. C.
,
Gard
,
S. A.
, and
Mesplay
,
K. P.
,
2004
, “
The Human Ankle During Walking: Implications for Design of Biomimetic Ankle Prostheses
,”
J. Biomech.
,
37
(
10
), pp.
1467
1474
.10.1016/j.jbiomech.2004.01.017
8.
Sup
,
F.
,
Bohara
,
A.
, and
Goldfarb
,
M.
,
2008
, “
Design and Control of a Powered Transfemoral Prosthesis
,”
Int. J. Rob. Res.
,
27
(
2
), pp.
263
273
.10.1177/0278364907084588
9.
Dermitzakis
,
K.
,
Carbajal
,
J. P.
, and
Marden
,
J. H.
,
2011
, “
Scaling Laws in Robotics
,”
Procedia Comput. Sci.
,
7
, pp.
250
252
.10.1016/j.procs.2011.09.038
10.
Vanderborght
,
B.
,
Albu-Schaeffer
,
A.
,
Bicchi
,
A.
,
Burdet
,
E.
,
Caldwell
,
D.
,
Carloni
,
R.
,
Catalano
,
M.
,
Eiberger
,
O.
,
Friedl
,
W.
,
Ganesh
,
G.
,
Garabini
,
M.
,
Grebenstein
,
M.
,
Grioli
,
G.
,
Haddadin
,
S.
,
Hoppner
,
H.
,
Jafari
,
A.
,
Laffranchi
,
M.
,
Lefeber
,
D.
,
Petit
,
F.
,
Stramigioli
,
S.
,
Tsagarakis
,
N.
,
Damme
,
M. V.
,
Ham
,
R. V.
,
Visser
,
L.
, and
Wolf
,
S.
,
2013
, “
Variable Impedance Actuators: A Review
,”
Rob. Auton. Syst.
,
61
(
12
), pp.
1601
1614
.10.1016/j.robot.2013.06.009
11.
Jutte
,
C. V.
, and
Kota
,
S.
,
2008
, “
Design of Nonlinear Springs for Prescribed Load–Displacement Functions
,”
ASME J. Mech. Des.
,
130
(
8
), p.
081403
.10.1115/1.2936928
12.
Au
,
S.
, and
Herr
,
H.
,
2008
, “
Powered Ankle-Foot Prosthesis
,”
IEEE Rob. Autom. Mag.
,
15
(
3
), pp.
52
59
.10.1109/MRA.2008.927697
13.
Haeufle
,
D.
,
Taylor
,
M.
,
Schmitt
,
S.
, and
Geyer
,
H.
,
2012
, “
A Clutched Parallel Elastic Actuator Concept: Towards Energy Efficient Powered Legs in Prosthetics and Robotics
,”
4th IEEE RAS & EMBS International Conference on Biomedical Robotics and Biomechatronics
(
BioRob 2012
),
Rome, Italy, June 24–27
, pp.
1614
1619
.10.1109/BioRob.2012.6290722
14.
Rouse
,
E. J.
,
Mooney
,
L. M.
,
Martinez-Villalpando
,
E. C
, and
Herr
,
H. M.
,
2013
, “
Clutchable Series-Elastic Actuator: Design of a Robotic Knee Prosthesis for Minimum Energy Consumption
,”
IEEE International Conference on Rehabilitation Robotics
(
ICORR 2013
), Seattle, WA, June 24–26. 10.1109/ICORR.2013.6650383
15.
Williams
,
R. J.
,
Hansen
,
A. H.
, and
Gard
,
S. A.
,
2009
, “
Prosthetic Ankle-Foot Mechanism Capable of Automatic Adaptation to the Walking Surface
,”
ASME J. Biomech. Eng.
,
131
(
3
), p.
035002
.10.1115/1.3005335
16.
Nickel
,
E. A.
,
Hansen
,
A. H.
, and
Gard
,
S. A.
,
2012
, “
Prosthetic Ankle-Foot System That Adapts to Sloped Surfaces
,”
ASME J. Med. Devices
,
6
(
1
), p.
011006
.10.1115/1.4005787
17.
Thorson
,
I.
, and
Caldwell
,
D.
,
2011
, “
A Nonlinear Series Elastic Actuator for Highly Dynamic Motions
,”
2011, IEEE/RSJ International Conference on Intelligent Robots and Systems
(
IROS
), San Francisco, CA, Sept. 25–30, pp.
390
394
.10.1109/IROS.2011.6094913
18.
Wolf
,
S.
, and
Hirzinger
,
G.
,
2008
, “
A New Variable Stiffness Design: Matching Requirements of the Next Robot Generation
,”
IEEE International Conference on Robotics and Automation
(
ICRA 2008
), Pasadena, CA, May 19–23, pp.
1741
1746
.10.1109/ROBOT.2008.4543452
19.
Vanderborght
,
B.
,
Tsagarakis
,
N. G.
,
Ham
,
R.
,
Thorson
,
I.
, and
Caldwell
,
D. G.
,
2011
, “
MACCEPA 2.0: Compliant Actuator Used for Energy Efficient Hopping Robot Chobino1D
,”
Auton. Rob.
,
31
(
1
), pp.
55
65
.10.1007/s10514-011-9230-7
20.
Migliore
,
S. A.
,
Brown
,
E. A.
, and
DeWeerth
,
S. P.
,
2007
, “
Novel Nonlinear Elastic Actuators for Passively Controlling Robotic Joint Compliance
,”
ASME J. Mech. Des.
,
129
(
4
), pp.
406
412
.10.1115/1.2429699
21.
Copilusi
,
C.
,
Dumitru
,
N.
,
Rusu
,
L.
, and
Marin
,
M.
,
2010
, “
Cam Mechanism Kinematic Analysis Used in a Human Ankle Prosthesis Structure
,” World Congress on Engineering, London, UK, June 30–July 2, pp.
1316
1320
.
22.
Legro
,
M.
,
Reiber
,
G.
,
del Aguila
,
M.
,
Ajax
,
M.
,
Boone
,
D.
,
Larsen
,
J.
,
Smith
,
D.
, and
Sangeorzan
,
B.
,
1999
, “
Issues of Importance Reported by Persons With Lower Limb Amputations and Prostheses
,”
J. Rehabil. Res. Dev.
,
36
(
3
), pp.
155
163
.
23.
Robert Brown
,
W.
, and
Galip Ulsoy
,
A.
,
2013
, “
A Maneuver Based Design of a Passive-Assist Device for Augmenting Active Joints
,”
ASME J. Mech. Rob.
,
5
(
3
), p.
031003
.10.1115/1.4024237
24.
Palmer
,
M. L.
,
2002
, “
Sagittal Plane Characterization of Normal Human Ankle Function Across a Range of Walking Gait Speeds
,” Master’s thesis,
Department Mechanical Engineering, Massachusetts Institute of Technology
,
Cambridge, MA
.
25.
Whittle
,
M. W.
,
2007
,
Gait Analysis: An Introduction
, 4th ed.,
Butterworth Heinemann
, Oxford, UK.
26.
Mettin
,
U.
,
La Hera
,
P. X.
,
Freidovich
,
L. B.
, and
Shiriaev
,
A. S.
,
2009
, “
Parallel Elastic Actuators as a Control Tool for Preplanned Trajectories of Underactuated Mechanical Systems
,”
Int. J. Rob. Res.
,
29
(
9
), pp.
1186
1198
.10.1177/0278364909344002
27.
Grimmer
,
M.
,
Eslamy
,
M.
,
Gliech
,
S.
, and
Seyfarth
,
A.
,
2012
, “
A Comparison of Parallel and Series Elastic Elements in an Actuator for Mimicking Human Ankle Joint in Walking and Running
,”
IEEE International Conference on Robotics and Automation
(
ICRA 2012
), St. Paul, MN, May 14–18, pp.
2463
2470
.10.1109/ICRA.2012.6224967
28.
Mathijssen
,
G.
,
Cherelle
,
P.
,
Lefeber
,
D.
, and
Vanderborght
,
B.
,
2013
, “
Concept of a Series-Parallel Elastic Actuator for a Powered Transtibial Prosthesis
,”
Actuators
,
2
(
3
), pp.
59
73
.10.3390/act2030059
29.
Hollander
,
K. W.
,
Ilg
,
R.
,
Sugar
,
T. G.
, and
Herring
,
D.
,
2006
, “
An Efficient Robotic Tendon for Gait Assistance
,”
ASME J. Biomech. Eng.
,
128
(
5
), pp.
788
791
.10.1115/1.2264391
30.
Hitt
,
J. K.
,
Sugar
,
T. G.
,
Holgate
,
M.
, and
Bellman
,
R.
,
2010
, “
An Active Foot-Ankle Prosthesis With Biomechanical Energy Regeneration
,”
ASME J. Med. Devices
,
4
(
1
), p.
011003
.10.1115/1.4001139
31.
Pratt
,
G.
, and
Williamson
,
M.
,
1995
, “
Series Elastic Actuators
,”
IEEE/RSJ International Conference on Intelligent Robots and Systems
, Pittsburgh, PA, Aug. 5–9, pp.
399
406
.10.1109/IROS.1995.525827
32.
Boyd
,
S.
, and
Vandenberghe
,
L.
,
2004
,
Convex Optimization
,
Cambridge University
Press, New York. 10.1017/CBO9780511804441
33.
Norton
,
R. L.
,
2009
,
Cam Design and Manufacturing Handbook
,
Industrial Press
, New York.
You do not currently have access to this content.