This article studies the design of passive elastic elements to reduce the actuator requirements for powered ankle prostheses. The challenge is to achieve most of the typically nonlinear ankle response with the passive element so that the active ankle-torque from the actuator can be small. The main contribution of this article is the design of a cam-based lower-limb prosthesis to achieve such a nonlinear ankle response. Results are presented to show that the addition of the cam-based passive element can reduce the peak actuator torque requirement substantially, by ∼74%. Moreover, experimental results are presented to demonstrate that the cam-based design can achieve a desired nonlinear response to within 10%.
Issue Section:
Research Papers
References
1.
U.S. Bureau of the Census
, 1995
, Statistical Abstract of the United States
, 115th ed., U.S. Bureau of the Census, Washington, DC
, p. 145
.2.
Fletcher
, D. D.
, Andrews
, K.
, Hallett
, J.
, Butters
, M.
, Rowland
, C.
, and Jacobsen
, S.
, 2002
, “Trends in Rehabilitation After Amputation for Geriatric Patients With Vascular Disease: Implications for Future Health Resource Allocation
,” Arch. Phys. Med. Rehabil.
, 83
(10
), pp. 1389
–1393
.10.1053/apmr.2002.346053.
Sun
, J.
, and Voglewede
, P. A.
, 2013
, “Powered Transtibial Prosthetic Device Control System Design, Implementation, and Bench Testing
,” ASME J. Med. Devices
, 8
(1
), p. 011004
.10.1115/1.40258514.
Versluys
, R.
, Beyl
, P.
, Van Damme
, M.
, Desomer
, A.
, Van Ham
, R.
, and Lefeber
, D.
, 2009
, “Prosthetic Feet: State-of-the-Art Review and the Importance of Mimicking Human Ankle-Foot Biomechanics
,” Disability Rehabil. Assistive Technol.
, 4
(2
), pp. 65
–75
.10.1080/174831008027150925.
Morgenroth
, D. C.
, Segal
, A. D.
, Zelik
, K. E.
, Czerniecki
, J. M.
, Klute
, G. K.
, Adamczyk
, P. G.
, Orendurff
, M. S.
, Hahn
, M. E.
, Collins
, S. H.
, and Kuo
, A. D.
, 2011
, “The Effect of Prosthetic Foot Push-Off on Mechanical Loading Associated With Knee Osteoarthritis in Lower Extremity Amputees
,” Gait Posture
, 34
(4
), pp. 502
–507
.10.1016/j.gaitpost.2011.07.0016.
Segal
, A. D.
, Zelik
, K. E.
, Klute
, G. K.
, Morgenroth
, D. C.
, Hahn
, M. E.
, Orendurff
, M. S.
, Adamczyk
, P. G.
, Collins
, S. H.
, Kuo
, A. D.
, and Czerniecki
, J. M.
, 2012
, “The Effects of a Controlled Energy Storage and Return Prototype Prosthetic Foot on Transtibial Amputee Ambulation
,” Hum. Mov. Sci.
, 31
(4
), pp. 918
–931
.10.1016/j.humov.2011.08.0057.
Hansen
, A. H.
, Childress
, D. S.
, Miff
, S. C.
, Gard
, S. A.
, and Mesplay
, K. P.
, 2004
, “The Human Ankle During Walking: Implications for Design of Biomimetic Ankle Prostheses
,” J. Biomech.
, 37
(10
), pp. 1467
–1474
.10.1016/j.jbiomech.2004.01.0178.
Sup
, F.
, Bohara
, A.
, and Goldfarb
, M.
, 2008
, “Design and Control of a Powered Transfemoral Prosthesis
,” Int. J. Rob. Res.
, 27
(2
), pp. 263
–273
.10.1177/02783649070845889.
Dermitzakis
, K.
, Carbajal
, J. P.
, and Marden
, J. H.
, 2011
, “Scaling Laws in Robotics
,” Procedia Comput. Sci.
, 7
, pp. 250
–252
.10.1016/j.procs.2011.09.03810.
Vanderborght
, B.
, Albu-Schaeffer
, A.
, Bicchi
, A.
, Burdet
, E.
, Caldwell
, D.
, Carloni
, R.
, Catalano
, M.
, Eiberger
, O.
, Friedl
, W.
, Ganesh
, G.
, Garabini
, M.
, Grebenstein
, M.
, Grioli
, G.
, Haddadin
, S.
, Hoppner
, H.
, Jafari
, A.
, Laffranchi
, M.
, Lefeber
, D.
, Petit
, F.
, Stramigioli
, S.
, Tsagarakis
, N.
, Damme
, M. V.
, Ham
, R. V.
, Visser
, L.
, and Wolf
, S.
, 2013
, “Variable Impedance Actuators: A Review
,” Rob. Auton. Syst.
, 61
(12
), pp. 1601
–1614
.10.1016/j.robot.2013.06.00911.
Jutte
, C. V.
, and Kota
, S.
, 2008
, “Design of Nonlinear Springs for Prescribed Load–Displacement Functions
,” ASME J. Mech. Des.
, 130
(8
), p. 081403
.10.1115/1.293692812.
Au
, S.
, and Herr
, H.
, 2008
, “Powered Ankle-Foot Prosthesis
,” IEEE Rob. Autom. Mag.
, 15
(3
), pp. 52
–59
.10.1109/MRA.2008.92769713.
Haeufle
, D.
, Taylor
, M.
, Schmitt
, S.
, and Geyer
, H.
, 2012
, “A Clutched Parallel Elastic Actuator Concept: Towards Energy Efficient Powered Legs in Prosthetics and Robotics
,” 4th IEEE RAS & EMBS International Conference on Biomedical Robotics and Biomechatronics
(BioRob 2012
), Rome, Italy, June 24–27
, pp. 1614
–1619
.10.1109/BioRob.2012.629072214.
Rouse
, E. J.
, Mooney
, L. M.
, Martinez-Villalpando
, E. C
, and Herr
, H. M.
, 2013
, “Clutchable Series-Elastic Actuator: Design of a Robotic Knee Prosthesis for Minimum Energy Consumption
,” IEEE International Conference on Rehabilitation Robotics
(ICORR 2013
), Seattle, WA, June 24–26. 10.1109/ICORR.2013.665038315.
Williams
, R. J.
, Hansen
, A. H.
, and Gard
, S. A.
, 2009
, “Prosthetic Ankle-Foot Mechanism Capable of Automatic Adaptation to the Walking Surface
,” ASME J. Biomech. Eng.
, 131
(3
), p. 035002
.10.1115/1.300533516.
Nickel
, E. A.
, Hansen
, A. H.
, and Gard
, S. A.
, 2012
, “Prosthetic Ankle-Foot System That Adapts to Sloped Surfaces
,” ASME J. Med. Devices
, 6
(1
), p. 011006
.10.1115/1.400578717.
Thorson
, I.
, and Caldwell
, D.
, 2011
, “A Nonlinear Series Elastic Actuator for Highly Dynamic Motions
,” 2011, IEEE/RSJ International Conference on Intelligent Robots and Systems
(IROS
), San Francisco, CA, Sept. 25–30, pp. 390
–394
.10.1109/IROS.2011.609491318.
Wolf
, S.
, and Hirzinger
, G.
, 2008
, “A New Variable Stiffness Design: Matching Requirements of the Next Robot Generation
,” IEEE International Conference on Robotics and Automation
(ICRA 2008
), Pasadena, CA, May 19–23, pp. 1741
–1746
.10.1109/ROBOT.2008.454345219.
Vanderborght
, B.
, Tsagarakis
, N. G.
, Ham
, R.
, Thorson
, I.
, and Caldwell
, D. G.
, 2011
, “MACCEPA 2.0: Compliant Actuator Used for Energy Efficient Hopping Robot Chobino1D
,” Auton. Rob.
, 31
(1
), pp. 55
–65
.10.1007/s10514-011-9230-720.
Migliore
, S. A.
, Brown
, E. A.
, and DeWeerth
, S. P.
, 2007
, “Novel Nonlinear Elastic Actuators for Passively Controlling Robotic Joint Compliance
,” ASME J. Mech. Des.
, 129
(4
), pp. 406
–412
.10.1115/1.242969921.
Copilusi
, C.
, Dumitru
, N.
, Rusu
, L.
, and Marin
, M.
, 2010
, “Cam Mechanism Kinematic Analysis Used in a Human Ankle Prosthesis Structure
,” World Congress on Engineering, London, UK, June 30–July 2, pp. 1316
–1320
.22.
Legro
, M.
, Reiber
, G.
, del Aguila
, M.
, Ajax
, M.
, Boone
, D.
, Larsen
, J.
, Smith
, D.
, and Sangeorzan
, B.
, 1999
, “Issues of Importance Reported by Persons With Lower Limb Amputations and Prostheses
,” J. Rehabil. Res. Dev.
, 36
(3
), pp. 155
–163
.23.
Robert Brown
, W.
, and Galip Ulsoy
, A.
, 2013
, “A Maneuver Based Design of a Passive-Assist Device for Augmenting Active Joints
,” ASME J. Mech. Rob.
, 5
(3
), p. 031003
.10.1115/1.402423724.
Palmer
, M. L.
, 2002
, “Sagittal Plane Characterization of Normal Human Ankle Function Across a Range of Walking Gait Speeds
,” Master’s thesis, Department Mechanical Engineering, Massachusetts Institute of Technology
, Cambridge, MA
.25.
Whittle
, M. W.
, 2007
, Gait Analysis: An Introduction
, 4th ed., Butterworth Heinemann
, Oxford, UK.26.
Mettin
, U.
, La Hera
, P. X.
, Freidovich
, L. B.
, and Shiriaev
, A. S.
, 2009
, “Parallel Elastic Actuators as a Control Tool for Preplanned Trajectories of Underactuated Mechanical Systems
,” Int. J. Rob. Res.
, 29
(9
), pp. 1186
–1198
.10.1177/027836490934400227.
Grimmer
, M.
, Eslamy
, M.
, Gliech
, S.
, and Seyfarth
, A.
, 2012
, “A Comparison of Parallel and Series Elastic Elements in an Actuator for Mimicking Human Ankle Joint in Walking and Running
,” IEEE International Conference on Robotics and Automation
(ICRA 2012
), St. Paul, MN, May 14–18, pp. 2463
–2470
.10.1109/ICRA.2012.622496728.
Mathijssen
, G.
, Cherelle
, P.
, Lefeber
, D.
, and Vanderborght
, B.
, 2013
, “Concept of a Series-Parallel Elastic Actuator for a Powered Transtibial Prosthesis
,” Actuators
, 2
(3
), pp. 59
–73
.10.3390/act203005929.
Hollander
, K. W.
, Ilg
, R.
, Sugar
, T. G.
, and Herring
, D.
, 2006
, “An Efficient Robotic Tendon for Gait Assistance
,” ASME J. Biomech. Eng.
, 128
(5
), pp. 788
–791
.10.1115/1.226439130.
Hitt
, J. K.
, Sugar
, T. G.
, Holgate
, M.
, and Bellman
, R.
, 2010
, “An Active Foot-Ankle Prosthesis With Biomechanical Energy Regeneration
,” ASME J. Med. Devices
, 4
(1
), p. 011003
.10.1115/1.400113931.
Pratt
, G.
, and Williamson
, M.
, 1995
, “Series Elastic Actuators
,” IEEE/RSJ International Conference on Intelligent Robots and Systems
, Pittsburgh, PA, Aug. 5–9, pp. 399
–406
.10.1109/IROS.1995.52582732.
Boyd
, S.
, and Vandenberghe
, L.
, 2004
, Convex Optimization
, Cambridge University
Press, New York. 10.1017/CBO978051180444133.
Norton
, R. L.
, 2009
, Cam Design and Manufacturing Handbook
, Industrial Press
, New York.Copyright © 2015 by ASME
You do not currently have access to this content.