This paper presents a framework and detailed vision for using immersive virtual reality (VR) environments to improve the design, verification, validation, and manufacture of medical devices. Major advances in medical device design and manufacture currently require extensive and expensive product cycles that include animal and clinical trials. The current design process limits opportunities to thoroughly understand and refine current designs and to explore new high-risk, high-payoff designs. For the past 4 years, our interdisciplinary research group has been working toward developing strategies to dramatically increase the role of simulation in medical device engineering, including linking simulations with visualization and interactive design. Although this vision aligns nicely with the stated goals of the FDA and the increasingly important role that simulation plays in engineering, manufacturing, and science today, the interdisciplinary expertise needed to realize a simulation-based visual design environment for real-world medical device design problems makes implementing (and even generating a system-level design for) such a system extremely challenging. In this paper, we present our vision for a new process of simulation-based medical device engineering and the impact it can have within the field. We also present our experiences developing the initial components of a framework to realize this vision and applying them to improve the design of replacement mechanical heart valves. Relative to commercial software packages and other systems used in engineering research, the vision and framework described are unique in the combined emphasis on 3D user interfaces, ensemble visualization, and incorporating state-of-the-art custom computational fluid dynamics codes. We believe that this holistic conception of simulation-based engineering, including abilities to not just simulate with unprecedented accuracy but also to visualize and interact with simulation results, is critical to making simulation-based engineering practical as a tool for major innovation in medical devices. Beyond the medical device arena, the framework and strategies described may well generalize to simulation-based engineering processes in other domains that also involve simulating, visualizing, and interacting with data that describe spatially complex time-varying phenomena.

1.
Chaikof
,
E. L.
, 2007, “
The Development of Prosthetic Heart Valves: Lessons in Form and Function
,”
N. Engl. J. Med.
0028-4793,
357
(
14
), pp.
1368
1371
.
2.
Butchart
,
E. G.
,
Li
,
H. H.
,
Payne
,
N.
,
Buchan
,
K.
, and
Grunkemeier
,
G. L.
, 2001, “
Twenty Years’ Experience With the Medtronic Hall Valve
,”
J. Thorac. Cardiovasc. Surg.
0022-5223,
121
(
6
), pp.
1090
1100
.
3.
Nkomo
,
V.
,
Gardin
,
J.
, and
Skelton
,
T.
, 2006, “
Mosaic Bioprosthesis: Ten Year Clinical Update
,”
The Lancet Online
, pp.
1005
1011
.
4.
Schultz
,
D. G.
, 2008,
FDA/NSF/NIH Workshop on Computer Methods in Cardiovascular Device Design and Evaluation
, Bethesda, MD, Mar. 19, Evening Keynote.
5.
U.S. Food and Drug Administration
, 2007, FDA’s Critical Path Initiative—Science Enhancing the Health and Well-Being of All Americans, http://www.fda.gov/oc/initiatives/criticalpath/initiative.htmlhttp://www.fda.gov/oc/initiatives/criticalpath/initiative.html
7.
Burriesci
,
G.
,
Marincola
,
F. C.
, and
Zervides
,
C.
, 2010, “
Design of a Novel Polymeric Heart Valve
,”
J. Med. Eng. Technol.
0309-1902,
34
(
1
), pp.
7
22
.
8.
Elizondo
,
D. R.
,
Boland
,
E. D.
,
Ambrus
,
J. R.
, and
Kurk
,
J. L.
, 1996, “
Mechanical Cardiac Valve Prostheses: Wear Characteristics and Magnitudes in Three Bileaflet Valves
,”
J. Heart Valve Dis.
0966-8519,
5
, pp.
S115
S123
.
9.
Medart
,
D.
,
Steinseifer
,
U.
,
Reul
,
H.
, and
Schmitz-Rode
,
T.
, 2006, “
Early Wear Development in a Novel Mechanical Heart Valve Prosthesis Made From Polymeric Materials
,”
J. Heart Valve Dis.
0966-8519,
15
(
5
), pp.
710
715
.
10.
Medart
,
D.
,
Schmitz
,
C.
,
Rau
,
G.
, and
Reul
,
H.
, 2005, “
Design and In Vitro Performance of a Novel Bileaflet Mechanical Heart Valve Prosthesis
,”
Int. J. Artif. Organs
0391-3988,
28
(
3
), pp.
256
263
.
11.
Van Nooten
,
G. J.
,
Taeymans
,
Y.
,
Belleghem
,
Y. V.
,
Francois
,
K.
,
Overbeke
,
H. V.
,
Poelaert
,
J.
,
Caes
,
F.
, and
Pauw
,
M. D.
, 2003, “
Lower Anticoagulation for Mechanical Heart Valves: Experience With the ATS Bileaflet Valve
,”
Heart Lung Circ.
,
12
(
3
), pp.
164
171
.
12.
Borazjani
,
I.
,
Ge
,
L.
, and
Sotiropoulos
,
F.
, 2010, “
Patient-Specific Simulations of Flow Through a Bileaflet Mechanical Heart Valve Implanted in an Anatomically Realistic Aorta
,”
Ann. Biomed. Eng.
0090-6964,
38
(
2
), pp.
326
344
.
13.
Borazjani
,
I.
,
Ge
,
L.
, and
Sotiropoulos
,
F.
, 2008, “
Curvilinear Immersed Boundary Method for Simulating Fluid Structure Interaction With Complex 3D Rigid Bodies
,”
J. Comput. Phys.
0021-9991,
227
(
16
), pp.
7587
7620
.
14.
Ge
,
L.
, and
Sotiropoulos
,
F.
, 2007, “
A Numerical Method for Solving the 3D Unsteady Incompressible Navier-Stokes Equations in Curvilinear Domains With Complex Immersed Boundaries
,”
J. Comput. Phys.
0021-9991,
225
(
2
), pp.
1782
1809
.
15.
Borazjani
,
I.
, and
Sotiropoulos
,
F.
, 2010, “
The Effect of Implantation Orientation of a Bi-Leaflet Mechanical Heart Valve on Kinematics and Hemodynamics in an Anatomic Aorta
,”
ASME J. Biomech. Eng.
0148-0731,
132
(
11
), p.
111005
.
16.
Sobel
,
J. S.
,
Forsberg
,
A. S.
,
Laidlaw
,
D. H.
,
Zeleznik
,
R. C.
,
Keefe
,
D. F.
,
Pivkin
,
I.
,
Karniadakis
,
G. E.
, and
Richardson
,
P.
, 2004, “
Particle Flurries: A Case Study of Synoptic 3D Pulsatile Flow Visualization
,”
IEEE Comput. Graphics Appl.
0272-1716,
24
, pp.
76
85
.
17.
Wenger
,
A.
,
Keefe
,
D. F.
,
Zhang
,
S.
, and
Laidlaw
,
D. H.
, 2004, “
Interactive Volume Rendering of Thin Thread Structures Within Multivalued Scientific Data Sets
,”
IEEE Trans. Vis. Comput. Graph.
1077-2626,
10
(
6
), pp.
664
672
.
18.
Coffey
,
D.
and
Keefe
,
D. F.
, 2010, “
BioWIM: A Multi-Surface, Multi-Touch Interface for Exploratory Visualization of Biomedical Data
,” Technical Report 10-025, University of Minnesota Department of Computer Science and Engineering.
You do not currently have access to this content.