The total product life cycle (TPLC) of medical devices has been defined by four stages: discovery and ideation, regulatory decision, product launch, and postmarket monitoring. Manufacturers of medical devices intended for use in the peripheral vasculature, such as stents, inferior vena cava (IVC) filters, and stent-grafts, mainly use computational modeling and simulation (CM&S) to aid device development and design optimization, supplement bench testing for regulatory decisions, and assess postmarket changes or failures. For example, computational solid mechanics and fluid dynamics enable the investigation of design limitations in the ideation stage. To supplement bench data in regulatory submissions, manufactures can evaluate the effects of anatomical characteristics and expected in vivo loading environment on device performance. Manufacturers might also harness CM&S to aid root-cause analyses that are necessary when failures occur postmarket, when the device is exposed to broad clinical use. Once identified, CM&S tools can then be used for redesign to address the failure mode and re-establish the performance profile with the appropriate models. The Center for Devices and Radiological Health (CDRH) wants to advance the use of CM&S for medical devices and supports the development of virtual physiological patients, clinical trial simulations, and personalized medicine. Thus, the purpose of this paper is to describe specific examples of how CM&S is currently used to support regulatory submissions at different phases of the TPLC and to present some of the stakeholder-led initiatives for advancing CM&S for regulatory decision-making.

References

1.
Office of the Commissioner,
2015
, “
CDRH Mission, Vision and Shared Values
,” FDA, Silver Spring, MD, accessed June 1, 2016, http://www.fda.gov/AboutFDA/CentersOffices/OfficeofMedicalProductsandTobacco/CDRH/ucm300639.htm
2.
Shuren, J.,
2015
, “
FDA CDRH Regulatory Science Report
,” FDA, Silver Spring, MD, accessed June 1, 2016, http://www.fda.gov/downloads/AboutFDA/CentersOffices/OfficeofMedicalProductsandTobacco/CDRH/CDRHReports/UCM274162.pdf
3.
Office of the Commissioner,
2011
, “
FDA's Strategic Plan for Advancing Regulatory Science
,” FDA, Silver Spring, MD, accessed June 1, 2016, http://www.fda.gov/ScienceResearch/SpecialTopics/RegulatoryScience/ucm267719.htm
4.
Lin
,
C. L.
,
Srivastava
,
A.
,
Coffey
,
D.
,
Keefe
,
D.
,
Horner
,
M.
,
Swenson
,
M.
, and
Erdman
,
A.
,
2014
, “
A System for Optimizing Medical Device Development Using Finite Element Analysis Predictions
,”
ASME J. Med. Devices
,
8
(
2
), pp. 020941-1–020941-3.
5.
Sim4Life
, 2010, “
Computable Human Phantoms
,” ZurichMedTech, Zurich, Switzerland, accessed June 1, 2016, http://www.zurichmedtech.com/sim4life
6.
Shuren, J.,
2016
, “
CDRH Regulatory Science and Research: Regulatory Science Priorities
,” FDA, Silver Spring, MD, accessed Sept. 1, 2016, http://www.fda.gov/downloads/MedicalDevices/ScienceandResearch/UCM467552.pdf
7.
Bardot, D.,
2015
, “
MDIC/Computer Modeling Project
,” The Medical Device Innovation Consortium, Minneapolis, MN, accessed June 1, 2016, http://mdic.org/computer-modeling/
8.
ASME V&V40 Subcommittee
,
2016
, “
Verification and Validation of Computational Modeling and Simulation—A Community Effort
,” Figshare, Silver Spring, MD, accessed Aug. 1, 2016, https://dx.doi.org/10.6084/m9.figshare.3468962.v1
9.
Morrison, T.M., and Lochner, D.L.,
2013
, “
FDA/NIH/NSF Workshop on Computer Models and Validation for Medical Devices
,” FDA Public Meetings, FDA White Oak Campus, Silver Spring, MD, June 11–12.
10.
Morrison
,
T. M.
,
2016
, “
Reporting of Computational Modeling Studies in Medical Device Submission—Guidance for Industry and FDA Staff
,” FDA Regulatory Information, Silver Spring, MD, accessed Oct. 2, 2016, http://www.fda.gov/downloads/MedicalDevices/DeviceRegulationandGuidance/GuidanceDocuments/UCM381813.pdf
11.
IEEE
,
2008
, “
Standard for the Validation of Computational Electromagnetics and Computer Modeling and Simulations
,” Institute of Electrical and Electronics Engineers, Piscataway, NJ, Standard No.
IEEE 1597.1-2008
.
You do not currently have access to this content.