Abstract

Fluid velocity or flow rate measurement, by flow sampling or bypassing flow from main pipelines, offers several advantages, like reducing the footprint of the flowmeter and avoiding the stoppage of a process during flowmeter repair or replacement. The flow measurement technique could be thermal mass flowmetry, a popular flow measurement method. A major limitation in the bypassing technique is the low flow rate through the bypass pipe resulting in a weak flowmeter thermal signal or reduced sensitivity to flow. This paper describes the usage of a validated computational fluid dynamics (CFD) model to investigate several bypass pipe designs to maximize fluid flow rate through the bypass pipes installed on the main pipeline and consequently maximize the thermal signal generated by an elementary thermal mass flowmeter installed on the bypass pipe. Investigations reveal that bypass design modification can improve thermal signal strength by as much as 38% with respect to that obtained in the baseline bypass design.

References

1.
Gajbhiye
,
B. D.
,
Kulkarni
,
H. A.
,
Tiwari
,
S. S.
, and
Mathpati
,
C. S.
,
2020
, “
Teaching Turbulent Flow Through Pipe Fittings Using Computational Fluid Dynamics Approach
,”
Eng. Rep.
,
2
(
1
), p. e12093.10.1002/eng2.12093
2.
Crawford
,
N. M.
,
Cunningham
,
G.
, and
Spence
,
S. W. T.
,
2007
, “
An Experimental Investigation Into the Pressure Drop for Turbulent Flow in 90° Elbow Bends
,”
Proc. Inst. Mech. Eng. E. J Process Mech. Eng.
,
221
(
2
), pp.
77
88
.10.1243/0954408JPME84
3.
Bullen
,
P. R.
,
Cheeseman
,
D. J.
,
Hussain
,
L. A.
, and
Ruffellt
,
A. E.
,
1987
, “
The Determination of Pipe Contraction Pressure Loss Coefficients for Incompressible Turbulent Flow
,”
Intl. J. Heat Fluid Flow
,
8
(
2
), pp.
111
118
.10.1016/0142-727X(87)90008-7
4.
Yuan
,
B. Z.
,
2003
, “
Hydraulic Design Procedure for Bypass Flow Meters Using a Pipe Bend
,”
Trans. ASAE (Am. Soc. Agric. Eng.)
, pp.
279
285
.https://elibrary.asabe.org/abstract.asp?aid=12978
5.
Nikpour
,
S.
,
Hejazi
,
F.
, and
Jaafar
,
M. S.
,
2018
, “
Development of a Divergent Fluid Wall Damper for Framed Structures Subjected to Dynamic Loads
,”
Struct. Control Health Monit.
,
25
(
3
), p.
e2108
.10.1002/stc.2108
6.
ANSYS,
Fluent Version 14.5
,
ANSYS
,
Canonsburg, PA
.
7.
Kim
,
S. J.
, and
Jang
,
S. P.
,
2001
, “
Experimental and Numerical Analysis of Heat Transfer Phenomena in a Sensor Tube of a Mass Flow Controller
,”
Int. J. Heat Mass Transfer
,
44
(
9
), pp.
1711
1724
.10.1016/S0017-9310(00)00216-7
You do not currently have access to this content.