The objective of this study is to develop an accurate, reliable, and updated predictive model for the air-side performance of flat-tube louver-fin heat exchangers. Using the most comprehensive experimental database to date—consisting of 1030 heat-transfer and 1270 pressure-drop measurements, from nine independent laboratories for 126 sample heat exchangers—- and -factor correlations are developed to predict the air-side performance of heat exchangers. The database is analyzed, the form of the curve fits is explored, and the predictive performance of the correlations is evaluated. The - and -factor correlations predict the experimental data with rms errors of 11.5% and 16.1%, respectively. Multiple regressions for a locally linearized data model were used to estimate the confidence intervals and covariances of the regression constants. A comparison to prior correlations shows the proposed correlations to provide more accurate predictions and to span a much broader parameter space than prior work. Practical utility in design and optimization, and unavoidable limitations in developing such correlations are discussed.
Skip Nav Destination
e-mail: ypark5@uiuc.edu
e-mail: a-jacobi@uiuc.edu
Article navigation
Research Papers
Air-Side Heat Transfer and Friction Correlations for Flat-Tube Louver-Fin Heat Exchangers
Young-Gil Park,
Young-Gil Park
Post-doctoral Research Associate
Department of Mechanical Science and Engineering,
e-mail: ypark5@uiuc.edu
University of Illinois
, 1206 West Green Street, Urbana, IL 61801
Search for other works by this author on:
Anthony M. Jacobi
Anthony M. Jacobi
Professor of Mechanical Engineering
Department of Mechanical Science and Engineering,
e-mail: a-jacobi@uiuc.edu
University of Illinois
, 1206 West Green Street, Urbana, IL 61801
Search for other works by this author on:
Young-Gil Park
Post-doctoral Research Associate
Department of Mechanical Science and Engineering,
University of Illinois
, 1206 West Green Street, Urbana, IL 61801e-mail: ypark5@uiuc.edu
Anthony M. Jacobi
Professor of Mechanical Engineering
Department of Mechanical Science and Engineering,
University of Illinois
, 1206 West Green Street, Urbana, IL 61801e-mail: a-jacobi@uiuc.edu
J. Heat Transfer. Feb 2009, 131(2): 021801 (12 pages)
Published Online: December 11, 2008
Article history
Received:
November 12, 2007
Revised:
September 15, 2008
Published:
December 11, 2008
Citation
Park, Y., and Jacobi, A. M. (December 11, 2008). "Air-Side Heat Transfer and Friction Correlations for Flat-Tube Louver-Fin Heat Exchangers." ASME. J. Heat Transfer. February 2009; 131(2): 021801. https://doi.org/10.1115/1.3000609
Download citation file:
Get Email Alerts
Cited By
Big MEMS for Thermal Measurement
J. Heat Mass Transfer
Aircraft Ducted Heat Exchanger Aerodynamic Shape and Thermal Optimization
J. Heat Mass Transfer
Related Articles
Experimental Study and Genetic-Algorithm-Based Correlation on Shell-Side Heat Transfer and Flow Performance of Three Different Types of Shell-and-Tube Heat Exchangers
J. Heat Transfer (September,2007)
Thermal Hydraulic Study of a Single Row Heat Exchanger With Helically Finned Tubes
J. Heat Transfer (June,2010)
Characterization of the Effect of Corrugation Angles on Hydrodynamic and Heat Transfer Performance of Four-Start Spiral Tubes
J. Heat Transfer (December,2001)
Flow and Heat Transfer Correlations for Porous Fin in a Plate-Fin Heat Exchanger
J. Heat Transfer (August,2000)
Related Proceedings Papers
Related Chapters
Hydrodynamic Mass, Natural Frequencies and Mode Shapes
Flow-Induced Vibration Handbook for Nuclear and Process Equipment
Incremental Model Adjustment
Nonlinear Regression Modeling for Engineering Applications: Modeling, Model Validation, and Enabling Design of Experiments
Design and Practice of Database in a Heat Exchanger CAD System
International Conference on Mechanical Engineering and Technology (ICMET-London 2011)