Experiments are conducted to study the heat transfer and pressure drop characteristics in a triangular duct cooled by an array of tangential jets, simulating the leading-edge cooling circuit of a turbine blade. Coolant ejected from a high-pressure plenum through an array of orifices is aimed at the leading-edge apex and exits from the radial outlets. Three different outflow orientations, namely coincident with the entry flow, opposed to the entry flow, and both, are tested for various Reynolds numbers 12600Re42000. A transient liquid crystal technique is used to measure the detailed heat transfer coefficients on two walls forming the leading-edge apex. Flow rate across each jet hole and the crossflow development, which are closely related to the local heat transfer characteristics, are also measured. Results show that increasing Re increases the heat transfer on both walls. The outflow orientation affects significantly the local heat transfer characteristics through influencing the jet flow together with the crossflow in the triangular duct. The triangular duct with two openings is recommended since it has the highest wall-averaged heat transfer and the moderate loss coefficient among the three outflow orientations investigated. Correlations for wall-averaged Nusselt number and loss coefficient in the triangular duct have been developed by considering the Reynolds number for three different outflow orientations. [S0022-1481(00)01204-4]

1.
Metzger
,
D. E.
, and
Vedula
,
R. P.
,
1987
, “
Heat Transfer in Triangular Channels with Angled Roughness Ribs on Two Walls
,”
Exp. Heat Transfer
,
1
, pp.
31
44
.
2.
Zhang
,
Y. M.
,
Gu
,
W. Z.
, and
Han
,
J. C.
,
1994
, “
Augmented Heat Transfer in Triangular Ducts with Full and Partial Ribbed Walls
,”
AIAA, J. Thermophys. Heat Transfer
,
8
, pp.
574
597
.
3.
Bunker
,
R. S.
, and
Metzger
,
D. E.
,
1990
, “
Local Heat Transfer in Internally Cooled Turbine Airfoil Leading Edge Regions: Part I-Impingement Cooling Without Film Coolant Extraction
,”
ASME J. Turbomach.
,
112
, pp.
451
458
.
4.
Chupp
,
R. E.
,
Helms
,
H. E.
,
McFadden
,
P. W.
, and
Brown
,
T. R.
,
1969
, “
Evaluation of Internal Heat-Transfer Coefficients for Impingement-Cooled Turbine Airfoils
,”
J. Aircr.
,
6
, pp.
203
208
.
5.
Kercher
,
D. M.
, and
Tabakoff
,
W.
,
1970
, “
Heat Transfer by a Square Array of Round Air Jets Impinging Perpendicular to a Flat Surface Including the Effect of Spent Air
,”
ASME J. Eng. Power
,
92
, pp.
73
82
.
6.
Florschuetz
,
L. W.
,
Berry
,
R. A.
, and
Metzger
,
D. E.
,
1980
, “
Periodic Streamwise Variations of Heat Transfer Coefficients for Inline and Staggered Arrays of Circular Jet with Crossflow of Spent Air
,”
ASME J. Heat Transfer
,
102
, pp.
132
137
.
7.
Florschuetz
,
L. W.
,
Truman
,
C. R.
, and
Metzger
,
D. E.
,
1981
, “
Streamwise Flow and Heat Transfer Distributions for Jet Array Impingement with Crossflow
,”
ASME J. Heat Transfer
,
103
, pp.
337
342
.
8.
Florschuetz
,
L. W.
,
Metzger
,
D. E.
, and
Su
,
C. C.
,
1984
, “
Heat Transfer Characteristics for Jet Array Impingement with Initial Crossflow
,”
ASME J. Heat Transfer
,
106
, pp.
34
41
.
9.
Priedeman
,
D.
,
Callahan
,
V.
, and
Webb
,
B. W.
,
1994
, “
Enhancement of Liquid Jet Impingement Heat Transfer with Surface Modifications
,”
ASME J. Heat Transfer
,
116
, pp.
486
489
.
10.
Van Treuren
,
K. W.
,
Wang
,
Z.
,
Ireland
,
P. T.
,
Jones
,
T. V.
,
1994
, “
Detailed Measurements of Local Heat Transfer Coefficient and Adiabatic Wall Temperature Beneath an Array of Impinging Jets
,”
ASME J. Turbomach.
,
116
, pp.
369
374
.
11.
Huang
,
Y.
,
Ekkad
,
S. V.
, and
Han
,
J. C.
,
1998
, “
Detailed Heat Transfer Distributions Under an Array of Orthogonal Impinging Jets
,”
AIAA. J. Thermophys. Heat Transfer
,
12
, pp.
73
79
.
12.
Ligrani
,
P. M.
,
Hedlund
,
C. R.
,
Thambu
,
R.
,
Babinchak
,
B. T.
,
Moon
,
H. K.
, and
Glezer
,
B.
,
1998
, “
Flow Phenomena in Swirl Chambers
,”
Exp. Fluids
,
24
, pp.
254
264
.
13.
Moon, H. K., O’Connell, T., and Glazer, B., 1998, “Heat Transfer Enhancement in a Circular Channel Using Lengthwise Continuous Tangential Injection,” International Heat Transfer Congress, Seoul, South Korea.
14.
Hedlund
,
C. R.
,
Ligrani
,
P. M.
,
Moon
,
H.-K.
, and
Glezer
,
B.
,
1999
, “
Heat Transfer and Flow Phenomena in a Swirl Chamber Simulating Turbine Internal Cooling
,”
ASME J. Turbomach.
,
121
, pp.
803
813
.
15.
Hedlund, C. R., and Ligrani, P. M., 1999, “Local Swirl Chamber Heat Transfer and Flow Structure at Different Reynolds Numbers,” ASME Paper No. 99-GT-164.
16.
Hwang
,
J. J.
, and
Cheng
,
C. S.
,
1999
, “
Augmented Heat Transfer in a Triangular Duct by Using Multiple Swirling Jets
,”
ASME J. Heat Transfer
,
121
, pp.
683
690
.
17.
Hwang
,
J. J.
, and
Lui
,
C. C.
,
1999
, “
Detailed Heat Transfer Characteristic Comparison in Straight and 90-deg Turned Trapezoidal Ducts with Pin-Fin Arrays
,”
Int. J. Heat Mass Transf.
,
42
, pp.
4005
4016
.
18.
Munson, B., Young, D., and Okiishi, T., 1994, “Fundamental of Fluid Mechanics,” 2nd Ed., John Wiley & Sons. Inc., New York.
19.
Hwang
,
J. J.
,
Lai
,
D. Y.
, and
Tsia
,
Y. P.
,
1999
, “
Heat Transfer and Pressure Drop in Trapezoidal Pin-Fin Ducts
,”
ASME J. Turbomach.
,
121
, pp.
264
272
.
20.
Kline
,
S. J.
, and
McClintock
,
F. A.
,
1953
, “
Describing Uncertainties in Single-Sample Experiments
,”
Mech. Eng. (Am. Soc. Mech. Eng.)
,
75
, pp.
3
8
.
21.
Dittus, F. W., and Boelter, L. M. K., 1930, University of California at Berkeley, Publications in Engineering, Vol. 2, p. 443.
22.
Cheng, C. S., 1998, “Enhancement of Heat Transfer and Friction in Triangular Ducts with an Array of Side-Entry Jets,” Master Thesis, Chung-Hua University, Taiwan (in Chinese).
23.
Petukhov, B. S., 1970, Advances in Heat Transfer, Academic, New York, Vol. 6, pp. 503–504.
You do not currently have access to this content.