Skip Nav Destination
Close Modal
Update search
Filter
- Title
- Author
- Author Affiliations
- Full Text
- Abstract
- Keyword
- DOI
- ISBN
- ISBN-10
- ISSN
- EISSN
- Issue
- Journal Volume Number
- References
- Conference Volume Title
- Paper No
Filter
- Title
- Author
- Author Affiliations
- Full Text
- Abstract
- Keyword
- DOI
- ISBN
- ISBN-10
- ISSN
- EISSN
- Issue
- Journal Volume Number
- References
- Conference Volume Title
- Paper No
Filter
- Title
- Author
- Author Affiliations
- Full Text
- Abstract
- Keyword
- DOI
- ISBN
- ISBN-10
- ISSN
- EISSN
- Issue
- Journal Volume Number
- References
- Conference Volume Title
- Paper No
Filter
- Title
- Author
- Author Affiliations
- Full Text
- Abstract
- Keyword
- DOI
- ISBN
- ISBN-10
- ISSN
- EISSN
- Issue
- Journal Volume Number
- References
- Conference Volume Title
- Paper No
Filter
- Title
- Author
- Author Affiliations
- Full Text
- Abstract
- Keyword
- DOI
- ISBN
- ISBN-10
- ISSN
- EISSN
- Issue
- Journal Volume Number
- References
- Conference Volume Title
- Paper No
Filter
- Title
- Author
- Author Affiliations
- Full Text
- Abstract
- Keyword
- DOI
- ISBN
- ISBN-10
- ISSN
- EISSN
- Issue
- Journal Volume Number
- References
- Conference Volume Title
- Paper No
NARROW
Date
Availability
1-20 of 42
Keywords: mechanical testing
Close
Follow your search
Access your saved searches in your account
Would you like to receive an alert when new items match your search?
1
Sort by
Journal Articles
In Vivo Quantification of Ascending Thoracic Aortic Aneurysm Wall Stretch Using MRI: Relationship to Repair Threshold Diameter and Ex Vivo Wall Failure Behavior
Available to PurchaseHuiming Dong, Henrik Haraldsson, Joseph Leach, Ang Zhou, Megan Ballweber, Chengcheng Zhu, Yue Xuan, Zhongjie Wang, Michael Hope, Frederick H. Epstein, Liang Ge, David Saloner, Elaine Tseng, Dimitrios Mitsouras
Journal:
Journal of Biomechanical Engineering
Publisher: ASME
Article Type: Research-Article
J Biomech Eng. December 2024, 146(12): 121009.
Paper No: BIO-23-1137
Published Online: October 3, 2024
... imaging. Moreover, aTAA wall stretch between surgical and nonsurgical patients was investigated. Finally, DENSE measurements were compared to reference-standard mechanical testing on aTAA specimens from surgical repairs. In total, 18 subjects were recruited, six healthy participants and 12 aTAA patients...
Topics:
Aneurysms,
Aorta,
Displacement,
Echoes,
Encryption,
Failure,
Imaging,
Magnetic resonance imaging,
Maintenance,
Mechanical testing
Includes: Supplementary data
Journal Articles
A Comparative Study of Machine Learning and Algorithmic Approaches to Automatically Identify the Yield Point in Normal and Aneurysmal Human Aortic Tissues
Available to Purchase
Journal:
Journal of Biomechanical Engineering
Publisher: ASME
Article Type: Technical Briefs
J Biomech Eng. April 2024, 146(4): 044503.
Paper No: BIO-23-1149
Published Online: February 15, 2024
... of the specimens. In a recent study, Chung et al. published an ML model capable of predicting rupture in abdominal aortic aneurysm that relied on computational finite element models informed by mechanical testing ( 26 ). It may be possible that further testing and validation of the ML model to predict yield...
Journal Articles
Simplified Mechanical Tests Can Simulate Physiological Mechanics of a Fixation Construct for Periprosthetic Femoral Fractures
Available to PurchaseXiang Chen, Casey A. Myers, Chadd W. Clary, Ryan J. DeWall, Bryan Fritz, Michael Blauth, Paul J. Rullkoetter
Journal:
Journal of Biomechanical Engineering
Publisher: ASME
Article Type: Research-Article
J Biomech Eng. March 2022, 144(3): 031003.
Paper No: BIO-21-1190
Published Online: October 11, 2021
... measurement of in vivo performance of the PFF fixation construct, it is unknown whether current standard mechanical tests or previous experimental and computational studies have appropriately reproduced the in vivo mechanics of the plate. To provide a basis for the evaluation and development of appropriate...
Journal Articles
Interpretation of Experimental Data is Substantial for Constitutive Characterization of Arterial Tissue
Available to Purchase
Journal:
Journal of Biomechanical Engineering
Publisher: ASME
Article Type: Technical Briefs
J Biomech Eng. October 2021, 143(10): 104501.
Paper No: BIO-21-1021
Published Online: June 16, 2021
...Ondřej Lisický; Anna Hrubanová; Jiří Burša The paper aims at evaluation of mechanical tests of soft tissues and creation of their representative stress–strain responses and respective constitutive models. Interpretation of sets of experimental results depends highly on the approach to the data...
Topics:
Biological tissues,
Constitutive equations,
Stress,
Mechanical testing,
Soft tissues,
Modeling
Includes: Supplementary data
Journal Articles
Journal:
Journal of Biomechanical Engineering
Publisher: ASME
Article Type: Research-Article
J Biomech Eng. September 2019, 141(9): 091005.
Paper No: BIO-19-1073
Published Online: August 2, 2019
.... Editor: Haichao Han. 13 02 2019 10 06 2019 incompressibility assumption biomechanics mechanical testing filtration IVUS volume fluid transport Current knowledge of venous tissue biomechanics is substantially lagging behind arterial tissue in both healthy and diseased...
Journal Articles
Effects of Elastase Digestion on the Murine Vaginal Wall Biaxial Mechanical Response
Available to PurchaseAkinjide R. Akintunde, Kathryn M. Robison, Daniel J. Capone, Laurephile Desrosiers, Leise R. Knoepp, Kristin S. Miller
Journal:
Journal of Biomechanical Engineering
Publisher: ASME
Article Type: Research-Article
J Biomech Eng. February 2019, 141(2): 021011.
Paper No: BIO-18-1172
Published Online: December 12, 2018
... in normal vaginal wall mechanics has not been fully ascertained. Therefore, the objective of this study is to investigate the contribution of elastic fibers to murine vaginal wall mechanics. Vaginal tissue from C57BL/6 female mice was mechanically tested using biaxial extension–inflation protocols before...
Topics:
Biological tissues,
Fibers,
Mechanical testing,
Stress,
Package on package,
Geometry,
Physiology
Includes: Supplementary data
Journal Articles
A Protocol for Measuring Pull-off Stress of Wound-Treatment Polymers
Available to Purchase
Journal:
Journal of Biomechanical Engineering
Publisher: ASME
Article Type: Technical Briefs
J Biomech Eng. July 2014, 136(7): 074501.
Paper No: BIO-13-1420
Published Online: May 12, 2014
... of the polymeric film. A uniaxial mechanical testing device (Electroforce T3200, Bose Corp., Minneapolis, MN) was utilized as a general support structure, a means for high accuracy and high volume data acquisition, and a constant-rate electric displacement actuator. Figure 1 shows a comprehensive assembly...
Journal Articles
Biomechanics of the Posterior Eye: A Critical Role in Health and Disease
Available to Purchase
Journal:
Journal of Biomechanical Engineering
Publisher: ASME
Article Type: Research-Article
J Biomech Eng. February 2014, 136(2): 021005.
Paper No: BIO-13-1422
Published Online: February 5, 2014
... microstructurally-informed models of ocular biomechanics. Here, we review notable findings and the consensus understanding on the biomechanics and microstructure of the posterior eye. Results from computational and numerical modeling studies and mechanical testing of ocular tissue are discussed. We conclude...
Journal Articles
Simulating Distal Radius Fracture Strength Using Biomechanical Tests: A Modeling Study Examining the Influence of Boundary Conditions
Available to Purchase
Journal:
Journal of Biomechanical Engineering
Publisher: ASME
Article Type: Technical Briefs
J Biomech Eng. November 2011, 133(11): 114501.
Published Online: November 18, 2011
... of the trabecular compartment compared to the more physiologically relevant intact wrist scenario. These differences should be borne in mind when interpreting the physiologic importance of mechanical testing and simulation results. 31 08 2011 01 11 2011 18 11 2011 18 11 2011 Boundary...
Journal Articles
Adaptation of a Planar Microbiaxial Optomechanical Device for the Tubular Biaxial Microstructural and Macroscopic Characterization of Small Vascular Tissues
Available to Purchase
Journal:
Journal of Biomechanical Engineering
Publisher: ASME
Article Type: Design Innovations
J Biomech Eng. July 2011, 133(7): 075001.
Published Online: July 29, 2011
... understanding of the phenomena seen on the macroscopic level. Unfortunately, mouse models present problems due to the size and delicate features in the mechanical testing of such tissues. In addition, some smaller arteries in large-animal studies (e.g., coronary and cerebral arteries) can present the same...
Journal Articles
A Preliminary Biomechanical Assessment of a Polymer Composite Hip Implant Using an Infrared Thermography Technique Validated by Strain Gage Measurements
Available to Purchase
Journal:
Journal of Biomechanical Engineering
Publisher: ASME
Article Type: Technical Briefs
J Biomech Eng. July 2011, 133(7): 074503.
Published Online: July 22, 2011
... gage measurements was used to investigate the stress and strain patterns in a novel composite hip implant made of carbon fiber reinforced polyamide 12 (CF/PA12). The hip implant was instrumented with strain gages and mechanically tested using average axial cyclic forces of 840 N, 1500 N, and 2100 N...
Journal Articles
Effect of Storage Duration on the Mechanical Behavior of Mouse Carotid Artery
Available to Purchase
Journal:
Journal of Biomechanical Engineering
Publisher: ASME
Article Type: Research Papers
J Biomech Eng. July 2011, 133(7): 071007.
Published Online: July 18, 2011
... ( 2 ), pp. 664 – 672 . 10.1152/japplphysiol.00118.2007 This work was supported in part by the National Institutes of Health (HL087563, HL105314) and by the National Science Foundation (REU0849621). We performed mechanical tests on mouse carotid arteries stored at 4°C in physiologic...
Journal Articles
Biomechanical Validation of Finite Element Models for Two Silicone Metacarpophalangeal Joint Implants
Available to Purchase
Journal:
Journal of Biomechanical Engineering
Publisher: ASME
Article Type: Technical Briefs
J Biomech Eng. February 2011, 133(2): 024501.
Published Online: January 31, 2011
.... FE models were validated using mechanical tests of implants incrementally bent from 0 deg to 90 deg in a joint simulator. Swanson size 2 and 4 implants were compared with NeuFlex size 10 and 30 implants, respectively. Good agreement was observed throughout the range of motion for the flexion bending...
Journal Articles
Quantifying Ligament Cross-Sectional Area via Molding and Casting
Available to Purchase
Journal:
Journal of Biomechanical Engineering
Publisher: ASME
Article Type: Research Papers
J Biomech Eng. September 2010, 132(9): 091012.
Published Online: September 1, 2010
...Kelly H. Schmidt; William R. Ledoux Ligament cross-sectional areas are difficult to determine because ligaments are soft tissues, can be very short, and may be deep between bones. However, accurate measurements are required for determining the material properties from mechanical testing. Many...
Journal Articles
High Strain Rate Testing of Bovine Trabecular Bone
Available to Purchase
Journal:
Journal of Biomechanical Engineering
Publisher: ASME
Article Type: Research Papers
J Biomech Eng. August 2010, 132(8): 081012.
Published Online: July 29, 2010
... of approximately 2–3 when the strain rate increases from 10 − 3 s − 1 to 500 s − 1 and that the bone fractures beyond a critical strain. 28 11 2005 28 05 2009 01 09 2009 29 07 2010 29 07 2010 biomechanics bone computerised tomography deformation mechanical testing...
Journal Articles
Deformable Mock Stenotic Artery With a Lipid Pool
Available to Purchase
Journal:
Journal of Biomechanical Engineering
Publisher: ASME
Article Type: Technical Briefs
J Biomech Eng. March 2010, 132(3): 034501.
Published Online: February 8, 2010
... artery, suitable for mechanical testing and intravascular imaging. Mock arteries were constructed in three phases using two molds: building a first layer of polyvinyl alcohol (PVA) cryogel, adding a lipid pool and building a second layer of PVA cryogel. To illustrate the deformation of the mock arteries...
Journal Articles
Characterization of the Fatigue Behavior of the Medial Collateral Ligament Utilizing Traditional and Novel Mechanical Variables for the Assessment of Damage Accumulation
Available to Purchase
Journal:
Journal of Biomechanical Engineering
Publisher: ASME
Article Type: Research Papers
J Biomech Eng. January 2010, 132(1): 011001.
Published Online: December 1, 2009
... 01 12 2009 01 12 2009 biological tissues biomechanics biomedical measurement creep elasticity fatigue mechanical testing tensile strength ligament biomechanics medial collateral ligament collagen fibers tangent stiffness secant stiffness chord stiffness...
Journal Articles
In Vitro Stretches of the Mitral Valve Anterior Leaflet Under Edge-to-Edge Repair Condition
Available to Purchase
Journal:
Journal of Biomechanical Engineering
Publisher: ASME
Article Type: Research Papers
J Biomech Eng. November 2009, 131(11): 111012.
Published Online: October 26, 2009
... of the anterior leaflet during diastole. 05 11 2008 03 06 2009 01 09 2009 26 10 2009 biomechanics biomedical imaging cardiology mechanical testing mitral valve edge-to-edge repair tissue mechanics A simple and promising mitral valve (MV) repair procedure, edge...
Journal Articles
Bioprinting Endothelial Cells With Alginate for 3D Tissue Constructs
Available to Purchase
Journal:
Journal of Biomechanical Engineering
Publisher: ASME
Article Type: Research Papers
J Biomech Eng. November 2009, 131(11): 111002.
Published Online: October 16, 2009
... investigated to determine a viable bioprinting process. The results indicated that the suitable fabrication parameters were 1.5% ( w / v ) sodium alginate and 0.5% ( w / v ) calcium chloride. Degradation studies via mechanical testing showed a decrease in the elastic modulus by 35% after 3 weeks. Cell...
Journal Articles
In Vivo Model for Evaluating the Effects of Mechanical Stimulation on Tissue-Engineered Bone Repair
Available to Purchase
Journal:
Journal of Biomechanical Engineering
Publisher: ASME
Article Type: Technical Briefs
J Biomech Eng. August 2009, 131(8): 084502.
Published Online: July 2, 2009
... compliant fixation plates with integrated elastomeric segments, which allow transduction of ambulatory loads. Multiaxially and uniaxially compliant plates were characterized by mechanical testing and evaluated using in vivo pilot studies. In the first study, experimental limbs were implanted with multiaxial...
1