Skip Nav Destination
Issues
October 1998
ISSN 0148-0731
EISSN 1528-8951
In this Issue
Research Papers
The Effect of Dimethylsulfoxide on the Water Transport Response of Rat Hepatocytes During Freezing
J Biomech Eng. October 1998, 120(5): 549–558.
doi: https://doi.org/10.1115/1.2834744
Topics:
Freezing
,
Water
,
Curve fitting
,
Temperature
,
Cooling
,
Cryonics
,
Equilibrium (Physics)
,
Ice
,
Liver
,
Permeability
Measurement of Water Transport During Freezing in Mammalian Liver Tissue: Part II—The Use of Differential Scanning Calorimetry
J Biomech Eng. October 1998, 120(5): 559–569.
doi: https://doi.org/10.1115/1.2834745
Topics:
Biological tissues
,
Differential scanning calorimetry
,
Freezing
,
Liver
,
Water
,
Dimensions
,
Microscopy
,
Biomedicine
,
Cooling
,
Curve fitting
Intracellular Calcium Dynamics During Photolysis
J Biomech Eng. October 1998, 120(5): 570–578.
doi: https://doi.org/10.1115/1.2834746
Effect of Intraluminal Thrombus Thickness and Bulge Diameter on the Oxygen Diffusion in Abdominal Aortic Aneurysm
J Biomech Eng. October 1998, 120(5): 579–583.
doi: https://doi.org/10.1115/1.2834747
Topics:
Aneurysms
,
Diffusion (Physics)
,
Oxygen
,
Thrombosis
,
Flow (Dynamics)
,
Computer software
,
Muscle
,
Rupture
,
Tension
Experimental Investigation of Oscillatory Flow Through a Symmetrically Bifurcating Tube
J Biomech Eng. October 1998, 120(5): 584–593.
doi: https://doi.org/10.1115/1.2834748
Topics:
Flow (Dynamics)
,
Bifurcation
,
Convection
,
Fluctuations (Physics)
,
Lung
,
Reynolds number
,
Shear (Mechanics)
,
Stability
,
Velocity measurement
,
Ventilation
Experiments on Steady and Oscillatory Flows at Moderate Reynolds Numbers in a Quasi-Two-Dimensional Channel With a Throat
J Biomech Eng. October 1998, 120(5): 594–601.
doi: https://doi.org/10.1115/1.2834749
Topics:
Flow (Dynamics)
,
Reynolds number
,
Deflection
,
Flow separation
,
Fluid pressure
,
Pressure
,
Shapes
Mechanical Analysis of Heterogeneous, Atherosclerotic Human Aorta
J Biomech Eng. October 1998, 120(5): 602–607.
doi: https://doi.org/10.1115/1.2834750
An Approach for the Stress Analysis of Transversely Isotropic Biphasic Cartilage Under Impact Load
J Biomech Eng. October 1998, 120(5): 608–613.
doi: https://doi.org/10.1115/1.2834751
Load Sharing Between Solid and Fluid Phases in Articular Cartilage: I — Experimental Determination of in Situ Mechanical Conditions in a Porcine Knee
J Biomech Eng. October 1998, 120(5): 614–619.
doi: https://doi.org/10.1115/1.2834752
Topics:
Cartilage
,
Fluids
,
Knee
,
Stress
,
Deformation
,
Biological tissues
,
Fibers
,
Materials properties
,
Modeling
,
Pressure transducers
Load Sharing Between Solid and Fluid Phases in Articular Cartilage: II — Comparison of Experimental Results and u-p Finite Element Predictions
J Biomech Eng. October 1998, 120(5): 620–624.
doi: https://doi.org/10.1115/1.2834753
Topics:
Cartilage
,
Finite element analysis
,
Fluids
,
Stress
,
Deformation
,
Biological tissues
,
Durability
,
Finite element model
,
Geometry
,
Knee
In Vivo Determination of the Direction of Rotation and Moment-Angle Relationship of Individual Elbow Muscles
J Biomech Eng. October 1998, 120(5): 625–633.
doi: https://doi.org/10.1115/1.2834754
Muscular Resistance to Varus and Valgus Loads at the Elbow
J Biomech Eng. October 1998, 120(5): 634–639.
doi: https://doi.org/10.1115/1.2834755
Topics:
Stress
,
Muscle
,
Electromyography
,
Stability
,
Musculoskeletal system
A Global Relationship Between Trabecular Bone Morphology and Homogenized Elastic Properties
J Biomech Eng. October 1998, 120(5): 640–646.
doi: https://doi.org/10.1115/1.2834756
Topics:
Bone
,
Elasticity
,
Biological tissues
,
Tensors
,
Anisotropy
,
Approximation
,
Optimization algorithms
,
Textiles
Creep Contributes to the Fatigue Behavior of Bovine Trabecular Bone
J Biomech Eng. October 1998, 120(5): 647–654.
doi: https://doi.org/10.1115/1.2834757
Topics:
Bone
,
Creep
,
Fatigue
,
Failure
,
Stress
,
Fracture (Materials)
,
Steady state
,
Cycles
,
Damage
,
Fatigue damage
Effects of Inserting a Pressensor Film Into Articular Joints on the Actual Contact Mechanics
J Biomech Eng. October 1998, 120(5): 655–659.
doi: https://doi.org/10.1115/1.2834758
Topics:
Contact mechanics
,
Cartilage
,
Accuracy and precision
,
Compression
,
Elastic moduli
,
Errors
,
Finite element model
,
Fluids
,
Geometry
,
Mechanical properties
Engineered Alignment in Media Equivalents: Magnetic Prealignment and Mandrel Compaction
J Biomech Eng. October 1998, 120(5): 660–666.
doi: https://doi.org/10.1115/1.2834759
A Parametric Study of Acetabular Cup Design Variables Using Finite Element Analysis and Statistical Design of Experiments
J Biomech Eng. October 1998, 120(5): 667–675.
doi: https://doi.org/10.1115/1.2834760
Topics:
Design
,
Experimental design
,
Finite element analysis
,
Stress
,
Bone
,
Finite element methods
,
Finite element model
,
Wear
,
Friction
,
Manufacturing
Simulation of the Superelastic Response of SMA Orthodontic Wires
J Biomech Eng. October 1998, 120(5): 676–685.
doi: https://doi.org/10.1115/1.2834761
Topics:
Simulation
,
Wire
,
Shape memory alloys
,
Boundary-value problems
,
Constitutive equations
,
Deformation
,
Elastic moduli
,
Shapes
Technical Briefs
An Elastic–Viscoplastic Model for Excised Facial Tissues
J Biomech Eng. October 1998, 120(5): 686–689.
doi: https://doi.org/10.1115/1.2834762
Topics:
Biological tissues
,
Skin
,
Deformation
,
Hardening
,
Elasticity
,
Physiology
,
Relaxation (Physics)
,
Stress
,
Constitutive equations