Based on the hypothesis that aggravating hemodynamic factors play a key role in the onset of arterial diseases, the methodology of “virtual prototyping” of branching blood vessels was applied to diseased external carotid artery (ECA) segments. The goals were to understand the underlying particle-hemodynamics and to provide various geometric design options for improved surgical reconstruction based on the minimization of critical hemodynamic wall parameters (HWPs). First, a representative carotid artery bifurcation (CAB) and then CABs with stenosed ECAs, i.e., a distally occluded ECA and an ECA stump, were analyzed based on transient three-dimensional blood flow solutions, employing a user-enhanced commercial finite volume code. Specifically, the HWPs, i.e., oscillatory shear index, wall shear stress angle gradient, near-wall residence time of monocytes, and near-wall helicity angle difference were evaluated to compare the merits of each design option, including a reconstructed near-optimal junction which generates the lowest HWP-values. The results provide physical insight to the biofluid dynamics of branching blood vessels and guide vascular surgeons as well as stent manufacturers towards interventions leading to high sustained patency rates.
Skip Nav Destination
Article navigation
April 2004
Technical Papers
Particle-Hemodynamics Simulations and Design Options for Surgical Reconstruction of Diseased Carotid Artery Bifurcations
S. Hyun,
S. Hyun
Department of Biomedical Engineering, Mercer University, Macon, GA 31207, USA
Search for other works by this author on:
C. Kleinstreuer,
C. Kleinstreuer
Department of Mechanical and Aerospace Engineering, North Carolina State University, Raleigh, NC 27695-7910, USA
Search for other works by this author on:
P. W. Longest,
P. W. Longest
Department of Mechanical and Aerospace Engineering, North Carolina State University, Raleigh, NC 27695-7910, USA
Search for other works by this author on:
C. Chen
C. Chen
Department of Mechanical and Aerospace Engineering, North Carolina State University, Raleigh, NC 27695-7910, USA
Search for other works by this author on:
S. Hyun
Department of Biomedical Engineering, Mercer University, Macon, GA 31207, USA
C. Kleinstreuer
Department of Mechanical and Aerospace Engineering, North Carolina State University, Raleigh, NC 27695-7910, USA
P. W. Longest
Department of Mechanical and Aerospace Engineering, North Carolina State University, Raleigh, NC 27695-7910, USA
C. Chen
Department of Mechanical and Aerospace Engineering, North Carolina State University, Raleigh, NC 27695-7910, USA
Contributed by the Bioengineering Division for publication in the JOURNAL OF BIOMECHANICAL ENGINEERING. Manuscript received by the Bioengineering Division December 29, 2002; revision received October 6, 2003. Associate Editor: C. R. Ethier.
J Biomech Eng. Apr 2004, 126(2): 188-195 (8 pages)
Published Online: May 4, 2004
Article history
Received:
December 29, 2002
Revised:
October 6, 2003
Online:
May 4, 2004
Citation
Hyun, S., Kleinstreuer, C., Longest , P. W., and Chen, C. (May 4, 2004). "Particle-Hemodynamics Simulations and Design Options for Surgical Reconstruction of Diseased Carotid Artery Bifurcations ." ASME. J Biomech Eng. April 2004; 126(2): 188–195. https://doi.org/10.1115/1.1688777
Download citation file:
Get Email Alerts
Estimation of Joint Kinetics During Manual Material Handling Using Inertial Motion Capture: A Follow-Up Study
J Biomech Eng (February 2025)
Effect of Compressive Strain Rates on Viscoelasticity and Water Content in Intact Porcine Stomach Wall Tissues
J Biomech Eng (February 2025)
Eyelid Motion Tracking During Blinking Using High-Speed Imaging and Digital Image Correlation
J Biomech Eng (January 2025)
Related Articles
Fluid Flow Structure in Arterial Bypass Anastomosis
J Biomech Eng (August,2005)
Construction of a Physical Model of the Human Carotid Artery Based Upon In Vivo Magnetic Resonance Images
J Biomech Eng (August,2001)
3D CAD Based Conceptual Design of a Novel Aortic Valve Stent
J. Med. Devices (June,2009)
Related Proceedings Papers
Related Chapters
Introduction and scope
Impedimetric Biosensors for Medical Applications: Current Progress and Challenges
Based on Blood Vessel Edge Feature Fundus Fluorescein Angiography Image Splicing
International Conference on Instrumentation, Measurement, Circuits and Systems (ICIMCS 2011)
Simulation of Thai Population Migration for Epidemiological Study
International Conference on Computer and Computer Intelligence (ICCCI 2011)