Vein grafts are subject to increased tensile stress due to exposure to arterial blood pressure, which has been hypothesized to induce endothelial cell (EC) and smooth muscle cell (SMC) injury. This study was designed to verify this hypothesis and to develop a tissue engineering approach that can be used to prevent these pathological events. Two experimental models were created in rats to achieve these goals: (1) a nonengineered vein graft with increased tensile stress, which was created by grafting a jugular vein into the abdominal aorta using a conventional end-to-end anastomotic technique; and (2) an engineered vein graft with reduced tensile stress, which was created by restricting a vein graft into a cylindrical sheath constructed using a polytetrafluoroethylene membrane. The integrity of ECs in these models was examined by using a silver nitrate staining method, and the integrity of SMCs was assessed by using a fluorescein phalloidin-labeling technique. It was found that nonengineered vein grafts were associated with early EC denudation with a change in EC coverage from 100 percent in normal jugular veins to 36±10, 28±12, 18±9, 44±15, 80±13, and 97±6 percent at 1 and 6 hours and 1, 5, 10, and 30 days, respectively. Similarly, rapid SMC actin filament degradation was found during the early period with a change in SMC coverage from ∼94 percent in normal jugular veins to 80±10, 41±17, 25±9, 51±15, 79±15, 98±2 percent at 1 and 6 hours and 1, 5, 10, and 30 days, respectively, in nonengineered vein grafts. In engineered vein grafts with reduced tensile stress, EC denudation and SMC actin filament degradation were prevented significantly. These results suggested that mechanical stretch due to increased tensile stress contributed to EC and SMC injury in experimental vein grafts, and these pathological events could be partially prevented when tensile stress was reduced by using a biomechanical engineering approach. [S0148-0731(00)00701-9]
Skip Nav Destination
Article navigation
February 2000
Technical Papers
Prevention of Mechanical Stretch-Induced Endothelial and Smooth Muscle Cell Injury in Experimental Vein Grafts
S. Q. Liu,
S. Q. Liu
Biomedical Engineering Department, Northwestern University, Evanston, IL 60208-3107
Search for other works by this author on:
M. M. Moore,
M. M. Moore
Biomedical Engineering Department, Northwestern University, Evanston, IL 60208-3107
Search for other works by this author on:
C. Yap
C. Yap
Biomedical Engineering Department, Northwestern University, Evanston, IL 60208-3107
Search for other works by this author on:
S. Q. Liu
Biomedical Engineering Department, Northwestern University, Evanston, IL 60208-3107
M. M. Moore
Biomedical Engineering Department, Northwestern University, Evanston, IL 60208-3107
C. Yap
Biomedical Engineering Department, Northwestern University, Evanston, IL 60208-3107
Contributed by the Bioengineering Division for publication in the JOURNAL OF BIOMECHANICAL ENGINEERING. Manuscript received by the Bioengineering Division January 7, 1999; revised manuscript received August 22, 1999. Associate Technical Editor: S. E. Rittgers.
J Biomech Eng. Feb 2000, 122(1): 31-38 (8 pages)
Published Online: August 22, 1999
Article history
Received:
January 7, 1999
Revised:
August 22, 1999
Citation
Liu , S. Q., Moore , M. M., and Yap , C. (August 22, 1999). "Prevention of Mechanical Stretch-Induced Endothelial and Smooth Muscle Cell Injury in Experimental Vein Grafts ." ASME. J Biomech Eng. February 2000; 122(1): 31–38. https://doi.org/10.1115/1.429625
Download citation file:
Get Email Alerts
Related Articles
Manipulation of Remodeling Pathways to Enhance the Mechanical Properties of a Tissue Engineered Blood Vessel
J Biomech Eng (December,2002)
Mechanical Properties of Rat Middle Cerebral Arteries With and Without Myogenic Tone
J Biomech Eng (February,2004)
Development of A Medical Device for Quantitative Physical Therapies
J. Med. Devices (June,2008)
Related Proceedings Papers
Related Chapters
Clinical issues and experience
Mechanical Blood Trauma in Circulatory-Assist Devices
Health and Safety and Emergency Response
Pipeline Transportation of Carbon Dioxide Containing Impurities
Introduction
Mechanical Blood Trauma in Circulatory-Assist Devices