Different types of stents are available to be implanted into blood-vessels (e.g., cardiovascular stent) or organs to maintain unobstructed blood flow or flow of tissue fluid through ducts (e.g., biliary and uretic stents and others). On the one hand, it is imperative to use smart material such that its mechanical and elastic properties meet those of the ideal stent. A smart stent can change the orientation of the material(s) either by sensing control, temperature, or blood pressure, thus alter the overall shape of the stent (wiggling). These wiggling motions can prevent or reduce the deposit of cholesterol inside the stent’s lumen. On the other hand, there is a need for a better physiological model of how the tensile and shear stresses of a blood vessel are altered as the blood pressure changes along a defined length of that vessel and how the shape changes of the blood vessel could prevent the deposits of lipid material on the vessel wall thereby possibly decrease the likelihood of stenosis. However, the design of an ideal stent is complicated by the lack of proper materials and modeling studies, and difficulties to have an optimized design because of complexities of environmental factors. In this literature review, we therefore propose that an optimal stents design should incorporate the use of highly biocompatible material(s) of well characterized properties and with an adequately modeled mechanical design. We have discussed the importance and relevance of these issues for future stent design and fabrication.
Skip Nav Destination
ASME 2007 International Mechanical Engineering Congress and Exposition
November 11–15, 2007
Seattle, Washington, USA
Conference Sponsors:
- ASME
ISBN:
0-7918-4303-3
PROCEEDINGS PAPER
Self-Cleansing Flexible Stent for Prevention of Clogging of Blood Vessels
Solomon W. Leung,
Solomon W. Leung
Idaho State University, Pocatello, ID
Search for other works by this author on:
Arya Ebrahimpour,
Arya Ebrahimpour
Idaho State University, Pocatello, ID
Search for other works by this author on:
Marco P. Schoen,
Marco P. Schoen
Idaho State University, Pocatello, ID
Search for other works by this author on:
James C. K. Lai
James C. K. Lai
Idaho State University, Pocatello, ID
Search for other works by this author on:
Solomon W. Leung
Idaho State University, Pocatello, ID
Arya Ebrahimpour
Idaho State University, Pocatello, ID
Marco P. Schoen
Idaho State University, Pocatello, ID
James C. K. Lai
Idaho State University, Pocatello, ID
Paper No:
IMECE2007-42118, pp. 195-202; 8 pages
Published Online:
May 22, 2009
Citation
Leung, SW, Ebrahimpour, A, Schoen, MP, & Lai, JCK. "Self-Cleansing Flexible Stent for Prevention of Clogging of Blood Vessels." Proceedings of the ASME 2007 International Mechanical Engineering Congress and Exposition. Volume 9: Mechanical Systems and Control, Parts A, B, and C. Seattle, Washington, USA. November 11–15, 2007. pp. 195-202. ASME. https://doi.org/10.1115/IMECE2007-42118
Download citation file:
13
Views
Related Proceedings Papers
Related Articles
Computational Fluid–Structure Interactions in the Human Cerebrovascular System: Part 1—A Review of the Current Understanding of Cerebrovascular Biomechanics
ASME J of Medical Diagnostics (August,2022)
Control of Circumferential Wall Stress and Luminal Shear Stress Within Intact Vascular Segments Perfused Ex Vivo
J Biomech Eng (October,2008)
Related Chapters
Part 2, Section II—Materials and Specifications
Companion Guide to the ASME Boiler and Pressure Vessel Code, Volume 1, Third Edition
Part 2, Section II—Materials and Specifications
Companion Guide to the ASME Boiler & Pressure Vessel Code, Volume 1, Second Edition
Two Advanced Methods
Applications of Mathematical Heat Transfer and Fluid Flow Models in Engineering and Medicine