Patients with hemiparesis often have limited functionality in the left or right hand. The standard therapeutic approach requires the patient to attempt to make use of the weak hand even though it is not functionally capable, which can result in feelings of frustration. Furthermore, hemiparetic patients also face challenges in completing many bimanual tasks, for example walker manipulation, that are critical to patients’ independence and quality of life. A prototype therapeutic device with two supernumerary robotic fingers was used to determine if robotic fingers could functionally assist a human in the performance of bimanual tasks by observing the pose of the healthy hand. Specific focus was placed on the identification of a straightforward control routine which would allow a patient to carry out simple manipulation tasks with some intermittent input from a therapist. Part of this routine involved allowing a patient to switch between active and inactive monitoring of hand position, resulting in additional manipulation capabilities. The prototype successfully enabled a test subject to complete various bimanual tasks using the robotic fingers in place of normal hand motions. From these results, it is clear that the device could allow a hemiparetic patient to complete tasks which would previously have been impossible to perform.
Skip Nav Destination
ASME 2015 Dynamic Systems and Control Conference
October 28–30, 2015
Columbus, Ohio, USA
Conference Sponsors:
- Dynamic Systems and Control Division
ISBN:
978-0-7918-5725-0
PROCEEDINGS PAPER
Supernumerary Robotic Fingers as a Therapeutic Device for Hemiparetic Patients
Teddy Ort,
Teddy Ort
Massachusetts Institute of Technology, Cambridge, MA
Search for other works by this author on:
Faye Wu,
Faye Wu
Massachusetts Institute of Technology, Cambridge, MA
Search for other works by this author on:
Nicholas C. Hensel,
Nicholas C. Hensel
Massachusetts Institute of Technology, Cambridge, MA
Search for other works by this author on:
H. Harry Asada
H. Harry Asada
Massachusetts Institute of Technology, Cambridge, MA
Search for other works by this author on:
Teddy Ort
Massachusetts Institute of Technology, Cambridge, MA
Faye Wu
Massachusetts Institute of Technology, Cambridge, MA
Nicholas C. Hensel
Massachusetts Institute of Technology, Cambridge, MA
H. Harry Asada
Massachusetts Institute of Technology, Cambridge, MA
Paper No:
DSCC2015-9945, V002T27A010; 7 pages
Published Online:
January 12, 2016
Citation
Ort, T, Wu, F, Hensel, NC, & Asada, HH. "Supernumerary Robotic Fingers as a Therapeutic Device for Hemiparetic Patients." Proceedings of the ASME 2015 Dynamic Systems and Control Conference. Volume 2: Diagnostics and Detection; Drilling; Dynamics and Control of Wind Energy Systems; Energy Harvesting; Estimation and Identification; Flexible and Smart Structure Control; Fuels Cells/Energy Storage; Human Robot Interaction; HVAC Building Energy Management; Industrial Applications; Intelligent Transportation Systems; Manufacturing; Mechatronics; Modelling and Validation; Motion and Vibration Control Applications. Columbus, Ohio, USA. October 28–30, 2015. V002T27A010. ASME. https://doi.org/10.1115/DSCC2015-9945
Download citation file:
54
Views
Related Proceedings Papers
Related Articles
Hybrid Optimal Control of a Flying+Sailing Drone
Letters Dyn. Sys. Control (January,0001)
A Vibration Absorption Method for Alleviating Impact of the Flexible Robotic Arm
J. Comput. Nonlinear Dynam (July,2017)
Model Synthesis for Design of Switched Systems Using a Variable Structure System Formulation
J. Dyn. Sys., Meas., Control (December,2003)
Related Chapters
A Digital-to-Analog Converter for Extreme Environments
Intelligent Engineering Systems through Artificial Neural Networks, Volume 16
Generators, Motors and Switch Gears
Handbook for Cogeneration and Combined Cycle Power Plants, Second Edition
Codes in Action Recent Highlights and Milestones
The Code: An Authorized History of the ASME Boiler and Pressure Vessel Code